Packing versus cavity Zone-Specific contributions to mass transfer in rotating packed bed absorption process
收藏DataCite Commons2025-11-03 更新2026-05-07 收录
下载链接:
https://rdb.p.lodz.pl/citation?persistentId=doi:10.34658/RDB.IR0BOE
下载链接
链接失效反馈官方服务:
资源简介:
A pilot-size rotating packed bed unit has been equipped with an infrared system for liquid phase analysis and a special interceptor that allows for online sampling of the absorbent solution at two points in the RPB: the outer periphery of the packing and the liquid outlet. Such a system allows to determine specific contributions of the packing zone and the cavity zone to the overall mass transfer. A standard chemical system of carbon dioxide and an aqueous solution of sodium hydroxide was used to determine reactive absorption efficiency under different packing and outer casing diameters, as well as varying rotational speeds, gas and liquid flow rates, and inlet absorbate concentrations. CO2 removal up to 27 % was achieved. Depending on geometrical configurations and process conditions, the cavity zone contribution in total absorption efficiency varied between 0 % and 46 %. Outer casing diameter had deciding effect on the mass transfer in the cavity zone, but it was also significantly affected by the packing size and rotational speed. This work was supported by the joint Polish-Czech project: no. UMO-2020/39/I/ST8/01381 financed by the National Science Centre, Poland, and no. GA 21-45227L financed by the Czech Science Foundation.
提供机构:
| Repozytorium Otwartych Danych Badawczych
创建时间:
2025-08-27