Cav3.2-/- Mouse #336 CA1 EEG recording
收藏NIAID Data Ecosystem2026-03-12 收录
下载链接:
https://zenodo.org/record/4561694
下载链接
链接失效反馈官方服务:
资源简介:
A Cav3.2-/- mouse (internal #336) was implanted with an intrahippocampal electrode for electrohippocampal CA1 EEG recordings. The differential electrode of the TA10ETA-F20 transmitter (Data Science International, DSI, USA, technical specifications: weight 3.9 g, volume 1.9 cc, input voltage range ± 2.5 mV, channel bandwidth (B) 1–200 Hz, nominal sampling rate (f) 1000 Hz (f = 5 B), temperature operating range 34–41 °C) was positioned at the following stereotaxic coordinates: (+)-lead, caudal − 2 mm, lateral of bregma 1.5 mm (right hemisphere), and dorsoventral (depth) 1.5 mm. The epidural reference electrode was positioned on the surface of the cerebellar cortex at the following stereotaxic coordinates: (−)-lead, bregma − 6 mm and lateral of bregma 1 mm (right
hemisphere). The deep tungsten electrodes (FHC, USA) are encapsuled with epoxylite with an
impedance of 50–100 kΩ (measured at 1000 Hz) and a shank diameter of 250 μm. For further details on the Cav3.2 mouse model, animal experimentation approval, anaesthesia, transmitter insertion, stereotaxic electrode implantation, postoperative pain management and recovery, please refer to Arshaad MI et al., 2021.
EEG data were exported to NeuroScore 3.2.9306-1 (Data Sciences International, DSI, USA). As the NeuroScore file format does not allow free access to the data, we have exported the raw EEG data as asci.-files, so that they can easily be imported in secondary analysis software. Importantly, the exported EEG data represent raw EEG data. No filtering, no artefact detection and/or artefact removal have been carried out. Thus, it is the users responsibility to adequately pretreat the data before further processing and analysis. As described in Arshaad MI et al. (2021), filtering, artefact detection and removal was carried out using NeuroScore before further analysis.
The EEG data are presented here as a zip-folder for size reasons. Four EEG recordings are exported: R1 (a first 24h long-term EEG recording 10 days post transmitter implantation), R2 (a second 24h long-term recording 17 days post transmitter implantation), U1 (a 6h EEG recording following the first urethane injection (800 mg/kg i.p.) at day 18 post transmitter implantation), U2 (a 6h EEG recording after a second urethane injection (800 mg/kg i.p.) at day 25 post transmitter implantation). In addition, relative activity values are exported for all four recordings. For details on the recording procedure, please refer to Arshaad MI et al. (2021).
创建时间:
2021-03-02



