five

Protein sialylation affects the pH-dependent binding of ferric ion to human serum transferrin - experimental data

收藏
NIAID Data Ecosystem2026-05-02 收录
下载链接:
https://zenodo.org/record/10881688
下载链接
链接失效反馈
官方服务:
资源简介:
Experimental data for a paper entitled Protein sialylation affects the pH-dependent binding of ferric ion to human serum transferrin (https://doi.org/10.1039/D4DT01311E).   Separate files are provided with the following information:   1. Experimental data: a) "Fluorescence + IFE corrections" worksheet contains the fluorescence data used for the subsequent calculations. Fluorescence values were measured in triplicate the Tecan Spark M10 multimode microplate reader using multiple z-positions (distance from the lens to the bottom of the microplate well) and baseline correction.  Fluorescence was corrected for the inner filter effect and normalized as described in the Supplementary Information (citation data will be updated pending publication). Additional information on the z-position inner filter effect correction method (ZINFE) can be found here: https://doi.org/10.1021/acs.analchem.2c01031. b) "Absorbance spectra" worksheet contains the averaged absorbance spectra and absorbance spectra of each replicated measurement.   2. Titrations The dependence of the measured fluorescence on the concentration of added FeNTA was modelled according to the binding polynomial for two iron binding sites (https://doi.org/10.1016/S0076-6879(08)04205-5). The results for all titrations are provided as separate files with 4 worksheets each: titration data, calculation of the free iron according to the binding polynomial (https://doi.org/10.1039/d3ay01261a), the least squares calculation of the fluorescence according to the binding polynomial for each data point using the solver routine in Excel, and the “jackknife” procedure for estimating the uncertainties of the titration parameters (https://doi.org/10.1021/ed075p119).  Separate files are provided for the determination of the active protein fraction and the fluorescence signal corresponding to the complete saturation of the binding sites.   3. Results and sensitivity analyses: Local sensitivity analysis was performed to assess the impact of concentration fluctuations on the uncertainties associated with the results. Concentrations were adjusted to both higher (H) and lower (L) estimates, based on adding or subtracting one standard deviation from the average concentrations, creating four scenarios: LL, LH, HL, HH. The results for all titrations are provided as separate files with 5 worksheets each: the results obtained directly from titration data and the results obtained by all 4 scenarios. Standard deviations of the obtained titration parameters were adjusted using this expanded set.   4. All data used for tables and plots in the manuscript, including statistical analyses and miscellaneous data: a) "Tables" worksheet contains all tables in the manuscript and the Supplementary Information (citation data will be updated pending publication), b) "fsp" worksheet contains the data on the pH-dependence of the site preference factor, fsp (https://doi.org/10.1042/bj1930717), c) "ΔΔrG" worksheet contains all ΔΔrG values reported in the manuscript, d) "Error propagation" contains the error propagation calculations for all values reported in the manuscript.
创建时间:
2024-07-10
二维码
社区交流群
二维码
科研交流群
商业服务