遇见数据集

M2

收藏
DataONE2024-06-22 更新2024-06-25 收录
官方服务:

资源简介:

M2 is one of six meteorological stations in the Zackenberg and Store Sødal Valley. Data from the station is found under meteorology (wind, temperature and relative humidity, short wave and long wave radiation, as well as NDVI), soil properties (soil moisture and soil heat flux) and snow properties (snow depth). M2 is located on a south facing slope in side the ZEROCALM-2 grid, in which active layer is monitored. The vegetation underneath the mast is dominated by salix arctica. Measurements at this station were initiated on the 5th of August 2003. The meteological data at M2 is recorded every half hour. Between 2003-2012 data was recorded using a CR10x campbell scientific data logger. In August 2012 this was changed to a CR1000 data logger. As the station is situated on a southfacing slope (dominating leeward side during winter in Zackenberg), the station has been covered in snow during several winters. E.g. during the winter 2014-15, whereafter the mast was tilted slightly towards the south. The tilt was corrected for on the 5th of August 2015 and we estimate that the tilt resulted in incoming shortwave radiation measurements of ~5 % more compared to earlier years. Unfortunately the tilt cannot be corrected for, as the correct inclination is unknown. Blank cells are missing values due to snow burial, power problems, broken sensors, data logger change, etc. Major data fall outs are: 2004: 2004.01.27 - 2004-02-08 and then every day until 2004.02.18 due to low battery voltage. 2005: 2005-01-06 - 2005.05.20 (except for two recordings in february), because the mast was out of level due to the weight of snow. 2006: 2006.02.11 - 2006.02.21 due to low battery voltage. 2008: 2008.02.10 - 2008.02.13 due to burial in snow and again from 2008.02.24 - 2008-05-13. During this burial the mast was compltely broken and all sensors that require the mast to be in level in order to give accurate measurements are missing until a new mast was installed 2008.08.13. Windsensors were also damaged during this burial, replaced in 2009. 2009: 2009.02.08 - 2009.03.24 daily dropouts due to low battery voltage. 2010: 2010-01-28 - 2010.05.29 due to dead internal battery. 2011: Several holes in October, due to batteryproblems, station dies 2011.11.17 due to low battery voltage, starts again 2012.04.14. 2012: 2011.11.17 - 2012.04.14 the station was also completely buried in snow and wind cup anemomter broken. Data from 2012.04.19 - 2012.05.02 is missing due to battery problems. And 2012.08.18 - 2012.08.25 due to data logger change. 2013: 2013.04.27 - 2013.04.30 due to problems with memorycard. 2017: Wind vanes A100R (measuring wind speed and gust) and W200P (wind direction and standard deviation) were exchanged with Young Alpine wind monitor (05103-45 Wind monitor), as well as temperature and relative humidity, April 29th. 2018: 2018-02 - 2018-06: due to snow burial.

M2是扎科贝格(Zackenberg)地区与Store Sødal谷内的6座气象站之一。该站点的观测数据涵盖气象要素(风速、气温、相对湿度、短波辐射、长波辐射以及归一化植被指数(NDVI))、土壤要素(土壤湿度与土壤热通量)以及积雪要素(积雪深度)。 M2位于ZEROCALM-2网格内的朝南坡地,该网格内开展了活动层(active layer)监测工作。站点桅杆下方的植被以北极柳(Salix arctica)为优势种。 该站点的观测工作于2003年8月5日正式启动。 M2站的气象观测数据每半小时采集一次。 2003年至2012年间,观测数据通过CR10X型坎贝尔科学(Campbell Scientific)数据采集器存储记录;2012年8月,该设备更换为CR1000型数据采集器。 由于站点地处朝南坡地(冬季为扎科贝格(Zackenberg)地区的主要背风侧),多个冬季均出现积雪掩埋站点的情况。例如2014-2015年冬季过后,桅杆向南发生轻微倾斜,该倾斜于2015年8月5日得到校正。经估算,此次倾斜导致入射短波辐射的观测值较往年偏高约5%。遗憾的是,因无法获知准确的倾斜角度,该观测偏差无法完全修正。 数据集中的空白单元格代表因积雪掩埋、供电故障、传感器损坏、数据记录仪更换等原因导致的缺失值。 主要的数据缺失时段如下: 2004年:因电池电压过低,2004年1月27日至2月8日无有效数据,且2月8日至2月18日期间每日均存在数据缺失。 2005年:2005年1月6日至5月20日无有效数据(仅2月有两次有效记录),原因为积雪重量导致桅杆失准。 2006年:2006年2月11日至2月21日因电池电压过低出现数据缺失。 2008年:2008年2月10日至2月13日因积雪掩埋出现数据缺失,2月24日至5月13日再次出现数据缺失。此次掩埋事件中桅杆完全损坏,所有依赖水平安装的传感器均无法提供准确观测值,直至2008年8月13日更换新桅杆后才恢复正常。本次事件中风速传感器亦遭到损坏,于2009年完成更换。 2009年:2009年2月8日至3月24日因电池电压过低出现每日数据缺失。 2010年:2010年1月28日至5月29日因内置电池耗尽出现数据缺失。 2011年:10月存在多处数据断点,因供电故障导致站点于2011年11月17日停止运行,2012年4月14日恢复工作。 2012年:2011年11月17日至2012年4月14日期间,站点完全被积雪掩埋,杯式风速计(cup anemometer)损坏。2012年4月19日至5月2日因供电故障出现数据缺失,8月18日至8月25日因更换数据记录仪出现数据缺失。 2013年:2013年4月27日至4月30日因存储卡故障出现数据缺失。 2017年:4月29日,用于测量风速与阵风的A100R型风标、用于测量风向与标准差的W200P型风标,以及气温与相对湿度传感器均更换为Young Alpine型风速监测仪(05103-45型风速监测仪)。 2018年:2018年2月至6月因积雪掩埋出现数据缺失。

创建时间:
2024-06-22
二维码
社区交流群
二维码
科研交流群
商业服务