Design considerations for an ultrahigh-bandwidth Phase Contrast Imaging system applied to fusion grade devices
收藏DataCite Commons2024-07-10 更新2024-07-13 收录
下载链接:
https://dataverse.harvard.edu/citation?persistentId=doi:10.7910/DVN/EC7E5N
下载链接
链接失效反馈官方服务:
资源简介:
The PCI diagnostic is an internal reference interferometer that creates an image of absolutely calibrated electron density fluctuations integrated along the line of sight of the probing light beam. While conventional PCI diagnostics installed on fusion experiments worldwide employ light of wavelength equal to 10.59 μm, the same system using light at 1.55 μm wavelength would extend the spectral response in wave-number and frequency by factors of seven and over one hundred, respectively, thereby potentially providing quantitative measurements of the internal structure of density perturbations induced by either turbulent or radio-frequency waves, simultaneously covering ion to electron gyro-radius scales up to the GHz frequency region. Based on a previously developed 1.55 μm PCI prototype system, constraints to the design for such a diagnostic in fusion grade devices are presented and compared to those faced with the conventional method.