Numerical study on the leakage characteristics of a scroll compressor.
收藏DataCite Commons2020-09-18 更新2025-04-16 收录
下载链接:
http://www.iifiir.org/clientBookline/service/reference.asp?INSTANCE=EXPLOITATION&OUTPUT=PORTAL&DOCID=IFD_REFDOC_0015588&DOCBASE=IFD_REFDOC_EN&SETLANGUAGE=EN
下载链接
链接失效反馈官方服务:
资源简介:
Scroll compressors have been used for various types of systems due to its advantages such as small size, simple structure, and high reliability. However, the refrigerant leakage in the scroll leads to a negative effect on the overall performance of a scroll compressor. In this study, a numerical simulation on a variable speed scroll compressor is carried out. The model contains heat/mass transfer and geometrical analysis for the characteristics of the refrigerant leakage. The model is validated by comparing the results with the experimental data for an R-410A heat pump. The mass flow rate and compressor power obtained from the simulation are within ± 6% and ± 4%, respectively, of the experimental data. The characteristics of the refrigerant leakage were analyzed theoretically and the variation of volumetric efficiency was also discussed in various operating conditions.
提供机构:
International Institute of Refrigeration (IIR)
创建时间:
2016-10-11