Thermodynamic analysis of a J-T heat exchanger used in G-M/J-T helium refrigerator for a cryoadsorption test facility.
收藏DataCite Commons2020-09-18 更新2025-04-16 收录
下载链接:
http://www.iifiir.org/clientBookline/service/reference.asp?INSTANCE=exploitation&OUTPUT=PORTAL&DOCID=IFD_REFDOC_0018367&DOCBASE=IFD_REFDOC&SETLANGUAGE=FR
下载链接
链接失效反馈官方服务:
资源简介:
A G-M/J-T helium refrigerator system is designed for a cryoadsorption test facility at 4.5K. The refrigerator includes a heat exchanger consisted by counterflow of J-T valve and a helically twined single finned-tube. A nonlinear variable specific heat capacity model for helium gas under 15K has been developed by the law of thermodynamics to study the thermal characteristics of the heat exchanger. Its performance is discussed for the test works in various operation conditions and the results indicate that weakening the interact surrounding environment and enhancing the number of Cr are practical and reasonable for the heat exchanger and useful for performance analysis of similar heat exchangers.
提供机构:
International Institute of Refrigeration (IIR)
创建时间:
2016-07-22