ASKAP Project AS103: Prototype Faraday rotation catalogs from the POSSUM pilot observations
收藏DataCite Commons2024-03-14 更新2025-04-09 收录
下载链接:
https://data.csiro.au/collection/csiro%3A62005v1
下载链接
链接失效反馈官方服务:
资源简介:
This collection contains post-processed image and catalog data products analyzed in Vanderwoude et al 2024.
Stokes IQU full image cubes:
POSSUM pilot I low-band observation SB10635, convolved to 21 arcsecond resolution across all frequency channels (cubes image.restored.*.SB10635.contcube.linmos.21arcsec.fits).
POSSUM pilot II low-band observation SB43773, convolved to 16.5 arcsecond resolution across all frequency channels (cubes image.restored.*.SB43773.band1.contcube.16.5arcsec.fits.
Stokes IQU uniform sensitivity regions:
These cubes are cutouts of the full image cubes, that contain the regions of uniform sensitivity in Vanderwoude et al (2024). The cutouts are slightly larger than the define regions to allow for spectrum extaction of components near the edge of the region. These cutouts include the low-band POSSUM pilot I observation SB10635 (cubes SB10635.*.uniform.sens.reg.fits) at 21 arcsecond resolution, the mid-band POSSUM pilot I observation SB10043 at 13 arcsecond resolution (cubes SB10043.*.uniform.sens.reg.13arcsec.fits) and 21 arcsecond resolution (cubes SB10043.i.uniform.sens.reg.21arcsec.fits; these were used to combine the low- and mid-band spectra), and the low-band POSSUM pilot II observation SB43773 at 16.5 arcsecond resolution (cubes SB43773.*.uniform.sens.reg.fits).
Multi-frequency synthesis Stokes I images:
Zeroth order multi-frequency Taylor series (Taylor 0) images for three observations: SB10635 (image.i.SB10635.cont.taylor.0.restored.conv.fits), SB10043 (image.i.SB10043.cont.taylor.0.restored.fits), and SB43773 (image.i.SB43773.cont.taylor.0.restored.conv.fits). These images were used to produce the total intensity component catalogues (described below).
Selavy total intensity component catalogues:
Total intensity component catalogues for three observations: SB10635 (selavy-image.i.SB10635.cont.taylor.0.restored.conv.components.xml), SB10043 (selavy-image.i.SB10043.cont.taylor.0.restored.components.xml), and SB43773 (selavy-image.i.EMU_1554-55_band1.SB43773.cont.taylor.0.restored.conv.components.xml). The Selavy source finder was run on the individual Stokes I Taylor 0 images (described above) to produce the respective component catalogues.
RM catalogues:
Faraday rotation measure (RM) catalogues for three observations (SB10635, SB10043, and SB43773) and a combined observation (SB10635 and SB10043), both with and without a median filter applied. The catalogues are in the RMTable standard format (2023ApJS..267...28V). Median filtered catalogues have "medfilt" in the name and unfiltered catalogues have "nofilt" in the name. The combined low- and mid-band pilot I observations have "combined" in the name.
提供机构:
CSIRO
创建时间:
2024-03-14



