Pulp Chamber Heating: An In Vitro Study Evaluating Different Light Sources and Resin Composite Layers

收藏
Figshare2016-12-01 更新2026-04-28 收录
下载链接:
https://figshare.com/articles/dataset/Pulp_Chamber_Heating_An_In_Vitro_Study_Evaluating_Different_Light_Sources_and_Resin_Composite_Layers/20003080
下载链接
链接失效反馈
官方服务:
资源简介:
Abstract The aim of the present in vitro study was to evaluate the temperature variation inside the pulp chamber during light-activation of the adhesive and resin composite layers with different light sources. Cavities measuring 8x10 mm were prepared on the buccal surface of bovine incisors, leaving a remaining dentin thickness of 1 mm. Specimens were placed in a 37±1 °C water bath to standardize the temperature. The temperature in the pulp chamber was measured every 10 s during 40 s of light activation of the adhesive system (SBMP-3M/ESPE) and in the three consecutive 1-mm-thick layers of resin composite (Z250-3M/ESPE). Three light source devices were evaluated: Elipar 2500 (QTH), LD Max (LED low irradiance) and VALO (LED high irradiance). The results were submitted to one-way ANOVA with repeated measures and Tukey's test, both with p