Effects of a thermodynamic non-equilibrium two-phase flow of R-600a at subcooled temperature condition on the performance of a vapor compression refrigeration system.

收藏
DataCite Commons2020-09-20 更新2025-04-16 收录
下载链接:
http://iifiir.org/clientBookline/service/reference.asp?INSTANCE=EXPLOITATION&OUTPUT=PORTAL&DOCID=IFD_REFDOC_0023479&DOCBASE=IFD_REFDOC_EN&SETLANGUAGE=EN
下载链接
链接失效反馈
官方服务:
资源简介:
Some previous research demonstrated the existence of a thermodynamic non-equilibrium two-phase flow of the refrigerant between the condenser outlet and the expansion device inlet even at thermodynamic subcooled temperature condition where the refrigerant temperature is below the corresponding saturation temperature. In the present study, experiments are carried out to investigate the effects of the thermodynamic non-equilibrium two-phase flow of R-600a at the subcooled condition on the performance of a vapor compression refrigeration system. The enthalpy of the non-equilibrium state refrigerant is calculated using three different methods. Based on the enthalpy values at the outlet of the condenser, the condenser heat rejection rate and the coefficient of performance (COP) of the refrigeration system are evaluated.