Disproportionation risk study for trifluoroethylene composition as low-GWP refrigerants.
收藏DataCite Commons2020-09-20 更新2025-04-16 收录
下载链接:
http://iifiir.org/clientBookline/service/reference.asp?INSTANCE=EXPLOITATION&OUTPUT=PORTAL&DOCID=IFD_REFDOC_0024831&DOCBASE=IFD_REFDOC_EN&SETLANGUAGE=EN
下载链接
链接失效反馈官方服务:
资源简介:
Trifluoroethylene (HFO-1123) and its mixtures are considered promising as next-generation Low-GWP (global warming potential) refrigerants. HFO-1123, however, has a potential for explosive disproportionation as with tetrafluoroethylene. The disproportionation risk of the HFO-1123 composition was investigated using a closed vessel explosion apparatus with an electric spark ignition system and evaluated in a risk assessment (RA) for applications in room air conditioners (RACs). Also investigated was the experimental minimum ignition energy (MIE) of the reaction. In this paper, the relationship between the electric spark energy and the molar density of HFO-1123 in the reaction is also discussed.
提供机构:
International Institute of Refrigeration (IIR)
创建时间:
2018-11-19