five

Data from: 3D printed digital pneumatic logic for the control of soft robotic actuators

收藏
Mendeley Data2024-04-14 更新2024-06-29 收录
下载链接:
https://datadryad.org/stash/dataset/doi:10.5061/dryad.jq2bvq8gv
下载链接
链接失效反馈
官方服务:
资源简介:
# 3D printed digital pneumatic logic for the control of soft robotic actuators [https://doi.org/10.5061/dryad.jq2bvq8gv ](https://doi.org/10.5061/dryad.jq2bvq8gv) This dataset contains the data and scripts that were used to generate the figures of the main text and supplements. All data was generated with pneumatic elements that were fabricated on a 3D printing platform as detailed in Conrad et al. (2020) (). The flexible parts, like valves and logic gates, described in this work have been printed in one continuous process with 'Recreus FilaFlex TPU A60' (shore hardness A 63), 'Recreus FilaFlex TPU A70' and 'Recreus FilaFlex TPU A82' with fitting print parameters (detailed in the supplements). This includes pneumatic connectors, channels and expandable membranes. Most parameters were set in the software 'PrusaSlic3r 2.4', which was used to prepare our models for printing. In a post processing step the files generated by the software were additionally modified to adapt the flow rate to the special needs of the flexible filament. ## Description of the data and file structure In the dataset the files are sorted by the figure or table they belong to. Inside the respective folders there are the raw data as well as the RStudio scripts that were used to calculate statistical tests as well as generate the figures. ## Explanation for data files Figure2File1.csv: Column 1 consists of the material of the used PLG in Shore hardness. Column 2 is the ID of the PLG. Column 3 is the valve of the PLG, where V1 is the normally-open valve and V2 is the normally-closed valve. Column 4 is the pressure at the socket S_t that was required to close the respective valve in bar. Figure2File2.txt: Column 1 shows the set pressure in bar at the input socket S_c1 of the PLG. Column 2 shows the measured mean pressure in bar at the input socket S_c1 for that pressure step. Column 3 is the mean pressure in bar at the socket S_t. Column 4 is the mean volumetric flow in ln/min through the PLG. Columns 5,6 and 7 are the respective standard deviations of the measured values for that pressure step. Column 8 is used to differentiate between the two experiments of measuring flow ('Durchfluss') and closing the valve ('Schliessen'). Column 9 specifies the tested valve and column 10 is the concatenated value of column 8 and 9. Figure2File3.txt: The columns are the same than in Figure2File2, but instead of specifying the valve, column 9 shows the direction of the signal (ASC = ascending/rising = 0 -> 1, DESC = descending/falling = 1 -> 0). Figure3File1-125.txt: Column 1 shows the set pressure in bar at the input socket S_t of the PLG. Column 2 shows the measured mean pressure in bar at the socket S_t. Column 3 shows the measured mean pressure in bar at the socket S_c. Column 4 is the mean volumetric flow in ln/min through the PLG. Columns 5,6 and 7 are the respective standard deviations of the measured values for that pressure step. Column 8 shows the direction of the signal (ASC = ascending/rising = 0 -> 1, DESC = descending/falling = 1 -> 0). Column 9 shows the set system pressure in bar at the socket S_p+. Column 10 specifies the valve of the PLG, where V1 is the normally-open valve and V2 is the normally-closed valve. Column 11 is the concatenated value of columns 8, 9 and 10. Figure3File1-250.txt: The columns are the same than in Figure3File1-125, but the system pressure is at 250 kPa instead of the 125 kPa. Figure3File2-125.txt: The columns are the same than in Figure3File1-125, but the values are from the NC valve instead of the NO valve. Figure3File2-250.txt: The columns are the same than in Figure3File1-250, but the values are from the NC valve instead of the NO valve. Figure3File3.txt: This file shows the maximum values for each combination of PLG, system pressure and direction of the signal. Column 1 shows the set pressure in bar at the input socket S_t of the PLG. Column 2 shows the measured mean pressure in bar at the socket S_t. Column 3 shows the measured mean pressure in bar at the socket S_p+. Column 4 is the mean volumetric flow in ln/min through the PLG. Column 5, 6 and 7 are the respective standard deviations of the measured values for that pressure step. Column 8 shows the direction of the signal (ASC = ascending/rising = 0 -> 1, DESC = descending/falling = 1 -> 0). Column 9 shows the set system pressure in bar at the socket S_p+. Column 10 is the concatenated values of column 8 and 9. Column 11 is the ID of the PLG. Figure4File1.txt: This file shows the measurement for the NOT-PLG. Column one shows the time in seconds. Column 2 shows the measured pressure at socket S_p+ in bar. Column 3 shows the measured pressure at socket S_c1 in bar. Column 4 shows the measured pressure at socket S_t in bar. Column 5 shows the measured pressure at socket S_c2 in bar. Column 6 shows the measure pressure at socket S_out in bar. Figure5File1.txt: This file shows the measurement for the AND-PLG. Column one shows the time in seconds. Column 2 shows the measured pressure at socket S_p+ in bar. Column 3 shows the measured pressure at socket S_t in bar. Column 4 shows the measured pressure at socket S_c2 in bar. Column 5 shows the measured pressure at socket S_out in bar. Figure5File2.txt: This file shows the measurement for the OR-PLG. Column one shows the time in seconds. Column 2 shows the measured pressure at socket S_p+ in bar. Column 3 shows the measured pressure at socket S_c1 in bar. Column 4 shows the measured pressure at socket S_t in bar. Column 5 shows the measured pressure at socket S_c2 in bar. Column 6 shows the measure pressure at socket S_out in bar. Figure6File1.txt: Column 1 shows the set system pressure in bar. Column 2 shows the measured mean time in seconds needed for an ascending input signal at socket S_t to create a status change in the output socket S_out. Column 3 shows the measured mean time in seconds needed for a descending input signal at socket S_t to create a status change in the output socket S_out. Columns 4 and 5 show the respective standard deviations of the measure values. Column 6 specifies the number of PLG connected in a row. Figure6File2.xlsx: Columns 1 to 6 show the same data than in Figure6File1.txt. They were used to calculate the normal equations from the observation equations and to fit a trend to the normal equations. The trend for the ascending slope is calculated in columns 8 to 16, the trend for the descending slope is calculated in columns 18 to 26. This was then used as the trend seen in Figure 6 B and C. Additionally, we subtracted the delay for a theoretical number of gates of 0, in order to remove the delay introduced by the measuring instruments. We included a reference in the script "Figure6.R" to show this. FigureS1File1.csv: Column 1 shows the set system pressure in bar. Column specifies the tested valve . Column 3 shows the direction of the signal (ASC = ascending/rising = 0 -> 1, DESC = descending/falling = 1 -> 0). Column 4 is the measured mean transition interval for the switching of the valve in bar. FigureS1File2.csv: This file has the same data than FigureS1File1.csv, but the two directions of the signal are pooled into one dataset. It is also the dataset used for figure S1. Please see the script "Figure S1.R" for the statistics. FigureS4File1.txt: Column 1 shows the maximum compression force in kN. Column 2 shows the ID of the PLG. Column 3 specifies which channel is beeing measured (1 = S_c1, 2 = S_c2). Column 4 shows the measured mean volumetric flow through that channel in ln/min. Column 5 shows the standard deviation of the measured mean volumetric flow. FigureS5File1.csv: Column 1 shows the ID of the PLG. Column 2 shows the maximum compression force in kN. Column 3 shows the direction of the signal (ASC = ascending/rising = 0 -> 1, DESC = descending/falling = 1 -> 0). Column 4 shows the repetition. Column 5 is the beginning of the edge of the signal in seconds. Column 6 is the end of the signal in seconds. Column 7 is the difference between the end and the start of the signal in seconds. Column shows the difference between the end and the start of the signal in seconds after subtracting the delay the measuring system introduces (calculated in Figure6File2.xlsx). TableS1File1.xlsx: Column shows the Shore hardness on the A scale of the PLG. Column 2 shows the ID of the PLG. Column 3 shows the maximum air pressure it resisted in bar. ## Code/Software All scripts were made and run in RStudio. The version used is RStudio 2023.03.1+446 "Cherry Blossom" Release (6e31ffc3ef2a1f81d377eeccab71ddc11cfbd29e, 2023-05-09) for windows.
创建时间:
2024-01-22
二维码
社区交流群
二维码
科研交流群
商业服务