five

Raw data: A thermal infrared hyperspectral camera based on a birefringent interferometer

收藏
NIAID Data Ecosystem2026-05-02 收录
下载链接:
https://zenodo.org/record/12952696
下载链接
链接失效反馈
官方服务:
资源简介:
In this repository we publish the raw data for the paper "A thermal infrared hyperspectral camera based on a birefringent interferometer" Data types: QCLst5: motor positions used to sample the interferogram of QCL at 5.263 µm [mm]Int5: corresponding intensity values of the interferogram of QCL at 5.263 µm as absolute value of the trace of the lock-in detector connected to the MCT [arbitrary counts]t7: motor positions used to sample the interferogram of QCL at 7.675 µm [mm]Int7: corresponding intensity values of the interferogram of QCL at 7.675 µm as absolute value of the trace of the lock-in detector connected to the MCT [arbitrary counts]t9: motor positions used to sample the interferogram of QCL at 9.073 µm [mm]Int9: corresponding intensity values of the interferogram of QCL at 9.073 µm as absolute value of the trace of the lock-in detector connected to the MCT [arbitrary counts]t9_short: motor positions used to sample the interferogram of QCL at 9.073 µm (shorter scan with smaller step) [mm]Int9_short: corresponding intensity values of the interferogram of QCL at 9.073 µm as absolute value of the trace of the lock-in detector connected to the MCT (shorter scan with smaller step) [arbitrary counts] DFG_origtDFG: motor positions used to sample the DFG signal [mm]IntDFG: corresponding intensity values of the DFG signal as absolute value of the trace of the lock-in detector connected to the MCT [arbitrary counts] DFGtDFG: motor positions used to sample the DFG signal, delay corrected, cropped, and centered [mm]IntDFG: corresponding intensity values of the DFG signal as absolute value of the trace of the lock-in detector connected to the MCT, low-frequency corrected, inverted and normalized to the mean [arbitrary counts] Kanthal_origtKanthal: motor positions used to sample the Kanthal signal [mm]IntKanthal: corresponding intensity values of the Kanthal signal as absolute value of the trace of the lock-in detector connected to the MCT [arbitrary counts] KanthaltKanthal: motor positions used to sample the Kanthal signal [mm]IntKanthal: corresponding intensity values of the Kanthal signal as absolute value of the trace of the lock-in detector connected to the MCT, linearly detrended, inverted and normalized to the mean [arbitrary counts] Quartzt: motor positions used to sample the quartz emission [mm]HyperMatrix: temporal hypercube of the quartz emission containing one bolometer image for every motor position [arbitrary counts] Filterst_Filters: motor positions used to sample the filters transmitted light [mm]HyperMatrix_Filters: temporal hypercube of the filters transmitted light containing one bolometer image for every motor position [arbitrary counts] Hotplatet_Hotplate: motor positions used to sample the hotplate emission [mm]HyperMatrix_Hotplate: temporal hypercube of the hotplate emission containing one bolometer image for every motor position [arbitrary counts]
创建时间:
2024-08-07
5,000+
优质数据集
54 个
任务类型
进入经典数据集
二维码
社区交流群

面向社区/商业的数据集话题

二维码
科研交流群

面向高校/科研机构的开源数据集话题

数据驱动未来

携手共赢发展

商业合作