five

Behavior of Auxetic Steel Wire RC Columns Exposed to Elevated Temperature

收藏
DataCite Commons2021-03-26 更新2024-07-28 收录
下载链接:
https://scielo.figshare.com/articles/dataset/Behavior_of_Auxetic_Steel_Wire_RC_Columns_Exposed_to_Elevated_Temperature/14268191/1
下载链接
链接失效反馈
官方服务:
资源简介:
Abstract Twenty-four rectangular RC column specimens, constructed at 1/3 scale, were tested under axial loading to investigate the use of ASWM (one, two, three, four, and five layers) exposed to elevated temperatures. Six of the column specimens were subjected to laboratory temperature (control or un-damaged specimens) of 23oC. Eighteen of the column specimens were subjected to elevated temperatures (six columns at 250oC, six columns at 500oC, and six columns at 750oC) for 2 hr. The obtained results clearly showed that each axial load resistance, toughness, and stiffness were all negatively affected by escalated temperature degrees. Also, the confinement effectiveness in terms of the ultimate load was decreased with the increase in concrete compressive strength (un-damaged). The number of ASWM layers significantly influenced the ductility, energy absorption, and ultimate load improvement percentage. The number of the ASWM layers considerably enhanced the ductility up to a certain number of erected layers; however, adding more layers had no apparent effect.
提供机构:
SciELO journals
创建时间:
2021-03-23
5,000+
优质数据集
54 个
任务类型
进入经典数据集
二维码
社区交流群

面向社区/商业的数据集话题

二维码
科研交流群

面向高校/科研机构的开源数据集话题

数据驱动未来

携手共赢发展

商业合作