Column breakthrough ion-exchange experiments for Amberlite IRC748 (WTP for Thala Valley clean-up)
收藏Research Data Australia2024-12-14 收录
下载链接:
https://researchdata.edu.au/column-breakthrough-ion-clean-up/698809
下载链接
链接失效反馈官方服务:
资源简介:
A series of ion-exchange column breakthrough experiments were undertaken with laboratory solutions spiked with heavy metals to investigate the removal of these metals by Amberlite IRC748 at variable salinity and temperature. Spreadsheets 1,2 contains sample ID descriptions for experiments at 20 degrees celsius, spreadsheet 3 contains sample ID descriptions for experiments at 20 degrees celsius (with a buffer), spreadsheet 4 contains sample ID descriptions for experiments at 4 degrees celsius, and spreadsheet 5 contains sample ID descriptions for the trial experiment. Spreadsheets 6,7,8,9,10,11,12 contain the raw data for the column experiments.#########Some terms and abbreviations used in these datasets are:LR - low rangeMR - mid rangeCorr - corrected for driftQC - in-house spiked standard (multicomponent metals)Rinse - de-ionised water rinse through ICP-MS to check for contamination or carryover NIST - NIST standard 1640: trace metal water standard (NIST stands for National Institute of Standards and Technology) Ref Values - expected values from analysis of the NIST standard DilBlk - dilution blankConcentration AVG - average concentration (of three readings)#########This work was carried out as part of ASAC project 1300 (ASAC_1300) - Development and application of technologies for the removal of heavy-metal contaminants from run-off associated with abandoned waste disposal sites.Some of the fields in this dataset are:IsotopeDilutionRinseAnalysisSampleSeawater
本数据集通过向重金属加标实验室模拟溶液开展一系列离子交换柱穿透实验,以探究Amberlite IRC748在不同盐度与温度条件下对重金属的去除效果。
工作表1、2包含20℃条件下实验的样品标识说明;工作表3对应20℃(添加缓冲剂)条件下的实验样品标识说明;工作表4为4℃条件下的实验样品标识说明;工作表5为预实验的样品标识说明。工作表6至12包含柱实验的原始数据。
本数据集使用的部分术语与缩写说明如下:
LR:低量程(low range)
MR:中量程(mid range)
Corr:漂移校正(corrected for drift)
QC:实验室加标标准物质(in-house spiked standard,多组分金属)
Rinse:去离子水冲洗(通过电感耦合等离子体质谱仪(ICP-MS)检测污染或残留)
NIST:美国国家标准与技术研究院(National Institute of Standards and Technology)标准1640:痕量金属水溶液标准(NIST为National Institute of Standards and Technology的缩写)
Ref Values:NIST标准样品分析所得参考值(expected values from analysis of the NIST standard)
DilBlk:稀释空白(dilution blank)
Concentration AVG:平均浓度(三次读数的平均值)
本研究为ASAC项目1300(ASAC_1300)——废弃废物处置场径流中重金属污染物去除技术的开发与应用的研究内容之一。
本数据集包含的部分字段如下:同位素(Isotope)、稀释(Dilution)、冲洗(Rinse)、分析(Analysis)、样品(Sample)、海水(Seawater)
提供机构:
Australian Antarctic Division