遇见数据集

A high-throughput 3D X-ray histology facility for biomedical research and preclinical applications - Supplementary Data

收藏
Zenodo2023-11-22 更新2026-05-26 收录
数据链接:
官方服务:

资源简介:

<strong>Videos</strong> <strong>Video 1</strong> A video going through the Z stack in single slices. This is a cross- sectional view of the XRH image stack along the XY plane. XRH datasets are normally oriented (resliced) in a way that a scroll through the stack along the XY plane emulates the physical histology slicing of the tissue. <strong>Video 2 </strong>A video going through the Y stack in single slices. This is a cross- sectional view of the XRH image stack along the XZ plane. XRH datasets are normally oriented (resliced) in a way that a scroll through the stack along the XY plane emulates the physical histology slicing of the tissue. <strong>Video 3 </strong>A video going through the X stack in single slices. This is a cross- sectional view of the XRH image stack along the YZ plane. XRH datasets are normally oriented (resliced) in a way that a scroll through the stack along the XY plane emulates the physical histology slicing of the tissue. <strong>Video 4 </strong>3D X-ray histology (XRH) is a µCT -based workflow tailored to fit seamlessly into current histology workflows in biomedical and pre-clinical research, as well as clinical histopathology. Microanatomical detail can be captured from standard (non-stained) formalin-fixed and paraffin-embedded (FFPE) tissue blocks. <strong>Video 5</strong> Average Intensity Projection (AIP) of the sample through the Histologically relevant plane. This is a 2D visualisation rendering the Average Intensity of 20x single XY slices along the z-axis of the stack. XRH datasets are normally oriented (resliced) in a way that a scroll through the stack along the XY plane emulates the physical histology slicing of the tissue. <strong>Video 6 </strong>Maximum Intensity Projection (MIP) of the sample through the Histologically relevant plane. This is a 2D visualisation rendering the Maximum Intensity of 20x single XY slices along the z-axis of the stack. XRH datasets are normally oriented (resliced) in a way that a scroll through the stack along the XY plane emulates the physical histology slicing of the tissue. <strong>Video 7 </strong>Standard deviation projection of the sample going through the histologically relevant plane. This is a 2D visualisation rendering the Standard Deviation of 20x single XY slices along the z- axis of the stack. XRH datasets are normally oriented (resliced) in a way that a scroll through the stack along the XY plane emulates the physical histology slicing of the tissue. <em>* <strong>Videos 5 -7</strong> are also referred to as "thick-slice rolls" </em>- <em>Thick-slice rolling is a 2D thick-slice viewing that allows rolling of a pre-selected number of slices (n) along the z-axis of the 3D data. A single thick-slice roll forwards is accomplished by translating the thick-slice by one single slice forwards; that is moving forward by one (+1) slice from the first and nth element and reapplying the criteria or operations to the new slice sub-stack.</em> <strong>The questionnaire used to collect feedback about the needs of the XRH community.</strong> Survey.docx Survey.pdf <strong>Exemplar report of a semi-automatically generated augmented PDF file</strong> that contain sample information, imaging settings, still images with descriptive figure legends, and links to corresponding online videos DEMO02019-FFPE_report_99EbPXG.pdf

提供机构:
Zenodo
创建时间:
2023-07-03
二维码
社区交流群
二维码
科研交流群
商业服务