CCS - CCS_SF_03 Mooring data May 2018 deployment
收藏Research Data Australia2026-01-17 收录
下载链接:
https://researchdata.edu.au/ccs-ccssf03-mooring-2018-deployment/1440763
下载链接
链接失效反馈官方服务:
资源简介:
Project Overview: A range of solutions will be required to reach globally agreed emissions reductions targets for carbon dioxide (CO2). Carbon capture and storage (CCS) is part of the suite of technologies that will contribute to lowering atmospheric emissions of CO2 from Australia's energy system. There are a wide variety of technologies at various stages of technical and commercial readiness, with more development underway for cost effective CO2 capture and storage. Our research will provide new knowledge to inform cost-efficient measurement, monitoring and verification (MMV) of the environment of CCS projects in coastal waters.\n\n--o--\n\nDescription:\n\nMeasurements are made Seabird Seaphox (for dissolved oxygen, pH, Seawater Temperature and Salinity), mounted on a lander. The Seaphox takes a reading every hour in the UTC hour and is transmitted real time through acoustic and/or 3G modems. The Seaphox consists of a SeaFET (pH) and SBE-37-SMP-ODO CTD (SW temperature, Salinity and Dissolved Oxygen [SBE63]).\n\nRelevant component details: make, model, serial number, firmware version, settings:\n\nSensor | Make | Model | Serial Number | Calibration\n\npH | Seaphox | SeaFET | 1001 | 2017-05, factory calibrated, verified by CSIRO lab\n\nDO | Seabird | SBE-37-SMP-ODO | 15560 | as above\n\nT and S | Seabird | SBE-63 | 1690 | as above\n\nCalibration Information (if applicable)\n\nSBE 37 (T, S, DO) and the SeaFET (pH) are calibrated by the factory and verified in the CSIRO laboratory. The pH reported in the files is flagged questionable for the pre-deployment calibrated data due to possible calibration changes which can occur after deployment\n\npH (calibrated) is further processed after the recovery using in situ bottle sample where available, using Total Alkalinity (TA) and Dissolved Inorganic Carbon (DIC), which will be converted to pH using CO2SYS, where the Lueker k1k2 dissociation constant is used.\n\nLocation: -38.2567, 147.4247
项目概述:为达成全球共识的二氧化碳(CO₂)减排目标,需配套一系列解决方案。碳捕获与封存(Carbon Capture and Storage,CCS)是助力降低澳大利亚能源系统向大气排放CO₂的技术组合之一。当前已有多种处于不同技术与商业化成熟度阶段的相关技术,且针对低成本高效的CO₂捕获与封存技术仍在推进更多研发工作。本研究将产出全新认知成果,为沿海水域CCS项目的兼具成本效益的测量、监测与验证(measurement, monitoring and verification,MMV)提供决策支撑。
--o--
数据集说明:
搭载于着陆器上的海鸟Seaphox设备(用于测量溶解氧、pH值、海水温度与盐度)将开展原位测量。该Seaphox设备于协调世界时(UTC)每小时整点采集一次数据,并通过声学调制解调器和/或3G调制解调器实时传输数据。Seaphox设备由SeaFET(pH传感器)与SBE-37-SMP-ODO CTD(用于测量海水温度、盐度与溶解氧[SBE63])组成。
相关组件详情:品牌、型号、序列号、固件版本、设置参数:
| 传感器类型 | 品牌 | 型号 | 序列号 | 校准信息 |
| ---- | ---- | ---- | ---- | ---- |
| pH | Seaphox | SeaFET | 1001 | 2017年5月出厂校准,经CSIRO实验室验证 |
| 溶解氧(DO) | Seabird | SBE-37-SMP-ODO | 15560 | 同上述校准情况 |
| 温度与盐度(T and S) | Seabird | SBE-63 | 1690 | 同上述校准情况 |
校准说明(如适用):
SBE 37(用于测量温度、盐度、溶解氧)与SeaFET(pH传感器)均经过出厂校准,并在CSIRO实验室完成验证。由于部署后可能出现校准偏移,部署前校准的pH数据已被标记为可疑。
若有可用的现场瓶装水样,回收后将结合总碱度(TA)与溶解无机碳(DIC)数据对已校准的pH值做进一步处理;处理过程将通过CO2SYS工具完成,并采用Lueker一级、二级解离常数进行换算。
采集位置:-38.2567, 147.4247
提供机构:
Commonwealth Scientific and Industrial Research Organisation