2016 Ecuador Earthquake
收藏DataCite Commons2021-03-09 更新2024-07-13 收录
下载链接:
https://datacenterhub.org/deedsdv/publications/view/535
下载链接
链接失效反馈官方服务:
资源简介:
<p>This dataset was last updated on August 23, 2016.</p> <p>The earthquake in Ecuador occurred on April 16, 2016 with a moment magnitude of 7.8. &nbsp;It caused more than 660 casualties and over 27,730 people were injured. &nbsp;The majority of the human casualties and damage to infrastructure were concentrated in the coastal province of Manab&iacute;. &nbsp;As of July 10, more than 2,100 aftershocks had been reported, including 11 aftershocks exceeding a magnitude of 6.0. &nbsp;</p> <p>&nbsp;<a href="/resources/14160/download/GOPR1317.JPG" target="_blank"><img alt="" src="/resources/14160/download/GOPR1317.JPG" style="height: 263px; width: 350px" /></a>&nbsp;&nbsp;<a href="/resources/14160/download/DSC_1865c.jpg" target="_blank"><img alt="" src="/resources/14160/download/DSC_1865c.jpg" style="height: 263px; width: 350px" /></a>&nbsp;&nbsp;</p> <p>Following the April 16, 2016 Ecuador earthquake, a team of researchers supported by the American Concrete Institute traveled to the province of Manab&iacute; in Ecuador to document the properties of reinforced concrete buildings affected by the earthquake. &nbsp;The reconnaissance group consisted of 3 teams (A, B, and C) with 3 to 4 people in each team. &nbsp;In Ecuador, the team worked with faculty and students of the Escuela Superior Polit&eacute;cnica del Litoral (ESPOL). &nbsp;The following people from&nbsp;ESPOL are gratefully acknowledged for their help with data collection: &nbsp;Pedro Rojas, Carlos Quishpe, David Lindao, Alixon Ocampo, Marianela Delgado, Reinaldo Salazar, David Valverde, and Jonatan Villavicencio.&nbsp;&nbsp;Without the invaluable support provided by ESPOL, the database created here would not have been possible. &nbsp;</p> <p>&nbsp;</p> <p>&nbsp;&nbsp;<img alt="" src="/resources/14160/download/aci.jpg" style="height: 200px; width: 375px" />&nbsp; &nbsp; <a href="/resources/14160/download/IMG_1852.JPG" target="_blank"><img alt="" src="/resources/14160/download/IMG_1852.JPG" style="height: 263px; width: 351px" /></a></p> <p>&nbsp;</p> <div>The survey was performed from July 10 through July 17, 2016 in the cities of Manta, Portoviejo, Chone, and Bah&iacute;a de <span style="mso-ansi-language: EN-US; mso-bidi-font-weight: bold; mso-bidi-language: AR-SA; mso-fareast-font-family: Calibri; mso-fareast-language: EN-US; mso-fareast-theme-font: minor-latin">Car&aacute;quez</span>, which are located in the province of Manab&iacute;. &nbsp;Approximately 170 low-rise buildings were surveyed. &nbsp;Data including photographs, structural and/or architectural drawings, dimensions, and GPS coordinates were collected for the buildings that were inspected.</div> <p><a href="/resources/14160/download/DSC_1586.JPG" target="_blank"><img alt="" src="/resources/14160/download/DSC_1586.JPG" style="height: 250px; width: 376px" /></a>&nbsp;&nbsp;<a href="/resources/14160/download/DSC_0261.JPG" target="_blank"><img alt="" src="/resources/14160/download/DSC_0261.JPG" style="height: 250px; width: 375px" /></a></p> <p><a href="/resources/14160/download/DSC_1774.JPG" target="_blank"><img alt="" src="/resources/14160/download/DSC_1774.JPG" style="height: 250px; width: 376px" /></a>&nbsp;&nbsp;<a href="/resources/14160/download/GOPR1339.JPG" target="_blank"><img alt="" src="/resources/14160/download/GOPR1339.JPG" style="height: 250px; width: 375px" /></a></p> <p>This database is presented as a spreadsheet with each row containing the following information for a building:</p> <ol> <li><strong>Title:</strong> Title of the project, group of experiments, simulations or surveys</li> <li><strong>Experiment or Case ID:</strong> ID assigned by the source to the sample, specimen, case, survey, site, experiment or simulation</li> <li><strong>Keywords:</strong> Words describing the dataset</li> <li><strong>Report(s):</strong> Related documentation</li> <li><strong>Parameters:</strong> Variables and parameters chosen by the researcher, compiler, professional or scientific organization to describe the data</li> <li><strong>Data:</strong> Data files generated through project. Tabular text format is preferred</li> <li><strong>Photos, Videos, etc.: </strong> Media files including photos, videos, audio generated through project</li> <li><strong>Drawings/Diagrams:</strong> Drawing and diagrams helpful to interpret the data</li> <li><strong>Source:</strong> Names of the people who generated the data</li> <li><strong>Experiment Start Date:</strong> Date when experiment started</li> <li><strong>Experiment End&nbsp;Date:</strong> Date when experiment ended</li> <li><strong>Latitude:</strong> Latitude of the location where data was collected, if applicable</li> <li><strong>Longitude:</strong> Longitude of the location where data was collected, if applicable</li> <li><strong>Compiled By:</strong> Names of the people who compiled the data</li> <li><strong>Compiled On:</strong> Date when the dataset was compiled<br /> <br /> In addition, the following information is presented in the parameter column:</li> </ol> <ol> <li>Title</li> <li>Experiment or Case ID</li> <li>Latitude</li> <li>Longitude</li> <li>Priority Index (Hassan Index, %):<br /> &nbsp;&nbsp;PI = WI + CI (where, WI = Wall Index, CI = Column Index)</li> <li>No. of Floors</li> <li>Total Floor Area (m2)</li> <li>Column Area (m2)</li> <li>Concrete Wall Area (NS) (m2)</li> <li>Concrete Wall Area (EW) (m2)</li> <li>Masonry Wall Area (NS) (m2)</li> <li>Masonry Wall Area (EW) (m2)</li> <li>Structural Damage - Three classes of damage<br /> a) Light: Hairline (crack width not exceeding approximate 0.13 mm) inclined and flexural cracks were observed in structural elements.<br /> b) Moderate: Wider cracks or spalling of concrete was observed.<br /> c) Severe: At least one element had a structural failure or at least one floor slab or part of it lost its elevation.</li> <li>Masonry Wall Damage - Damage to infill walls classified as follows:<br /> a) Light: Hairline cracks occurred.<br /> b) Moderate: Wider cracks appeared or large pieces of plaster flaked off.<br /> c) Severe: The element collapsed or cracks wide enough to see through the wall appeared.</li> <li>Captive Columns: Are there captive columns?</li> <li>Column Index (%)<br /> &nbsp;&nbsp;&nbsp;CI = 0.5 Acol/Af *100%<br /> &nbsp;&nbsp;where,<br /> &nbsp;&nbsp;Acol: the sum of cross-sectional areas of all columns at ground floor.<br /> &nbsp;&nbsp;Af: total floor area above ground level</li> <li>Wall Index (NS) (%)<br /> &nbsp;&nbsp;WI = (Acw + 0.1Amw)/Af *100%<br /> &nbsp;&nbsp;where,<br /> &nbsp;&nbsp;Acw: the sum of cross-sectional areas of reinforced concrete walls in north-south direction at ground floor<br /> &nbsp;&nbsp;Amw: the sum of cross-sectional areas of infill masonry walls in north-south direction at ground floor</li> <li>Wall Index (EW) (%)<br /> &nbsp;&nbsp;WI = (Acw + 0.1Amw)/Af *100%<br /> &nbsp;&nbsp;where,<br /> &nbsp;&nbsp;Acw: the sum of cross-sectional areas of reinforced concrete walls in east-west direction at ground floor<br /> &nbsp;&nbsp;Amw: the sum of cross-sectional areas of infill masonry walls in east-west direction at ground floor</li> <li>Min WI (%)<br /> &nbsp;&nbsp;Minimum Wall Index</li> <li>Report(s)</li> <li>Data</li> <li>Photos, Videos, etc.</li> <li>Drawings/Diagrams</li> </ol> <nb:citations></nb:citations>
提供机构:
DEEDSHub
创建时间:
2021-03-09



