Statistical correlation analysis on indoor air high-priority pollutants in Spanish public primary schools [Dataset]
收藏DataCite Commons2025-11-12 更新2025-04-10 收录
下载链接:
https://edatos.consorciomadrono.es/citation?persistentId=doi:10.21950/RUCDVO
下载链接
链接失效反馈官方服务:
资源简介:
The project conducted presents a comprehensive assessment of indoor air quality in public primary schools across Madrid (Spain). Several classrooms have been monitored for a year, registering indoor air concentrations and outdoor ambient levels. Later, a statistical analysis has been performed to explore correlations between indoor air pollutant concentrations during occupied and unoccupied periods, as well as the impact of student activities and classroom operation, among other factors.
The dataset provides monitoring information of indoor and outdoor variables included in one file named as "Dataset_SchoolMonitoring.csv". Specifically, four Public Primary Schools were monitored in Madrid (Spain), registering indoor air quality data (from 2 to 3 classrooms per school) and outdoor air quality information from both punctual measurements and a local weather station close to the schools.Punctual monitoring measures were conducted during February, April, May, October and December in 2023.
Specifically, indoor variables monitored in the classrooms are refered to:
- TVOC (ppb)
- Ultrafine PM (from 0.02 to 1 μm) (part./cm3)
- PM0.3 (part./cm3and μg/m3)
- PM1 (part./cm3 and μg/m3)
- PM2.5 (part./cm3 and μg/m3)
- CO2 (ppm)
- Temperature (ºC)
- Relative Humidity (%)
- Formaldehyde (µg/m3)
Also, punctual outdoor measurements of the aforementioned parameters have been also included in the dataset. Additionally, outdoor variables recorded in a local weather station have also been incorporated into the dataset:
- Wind speed (m/s)
- Wind direction (º)
- Outdoor temperature (ºC)
- Outdoor Relative humidity (%)
- Atmospheric pressure (mb)
- Solar Radiation (W/m2)
- Rain (l/m2)
- NO (µg/m3)
- NO2 (µg/m3)
- PM10 (µg/m3)
- Nox (µg/m3)
- O3 (µg/m3)
Furthermore, indoor students interaction and classroom operation aspects are incorporated into the study through several variables, which are assigned two possible values: 1 means "Open, ON, Considered"; while 0 means "Closed, OFF, None":
- Door opening (1/0)
- Window opening (1/0)
- Artificial lights operation (1/0)
- Students’ interaction (Activity) (1/0)
- VOC emissions (Materials) (1/0)
- PM emissions (1/0)
- Technological devices (1/0)
A more detail description of each variable may be found in the paper referenced in the Related publication section.
提供机构:
e-cienciaDatos
创建时间: