five

AMRI 00-N-0082 natural stimuli

收藏
OpenNeuro2025-09-11 更新2026-03-14 收录
下载链接:
https://openneuro.org/datasets/ds006654
下载链接
链接失效反馈
官方服务:
资源简介:
![](Banner_Mandelkow2017_fMRI.jpg) #### *How does the accuracy of machine-learning classifiers depend on fMRI resolution?* High-field (7T) high-resolution (1.2mm) fMRI and eye tracking data from human subjects repeatedly watching 5-minute clips of naturalistic (cinematic) movie content without sound. A high number of repeated stimulus presentations and fMRI acquisitions at two different resolutions (1.2mm and 2mm isotropic) were chosen to investigate the accuracy of machine-learning classifiers and to test its dependence on fMRI resolution. Please find details in below publication [Mandelkow et al. 2017](https://doi.org/10.1016/j.neuroimage.2017.08.053), which should be quoted as a reference. All data were acquired at the National Institutes of Health under NINDS protocol 00-N-0082 in 2012-2015. **Effects of spatial fMRI resolution on the classification of naturalistic movies**, H. Mandelkow, J.A. de Zwart, J.H. Duyn, 2017, NeuroImage https://doi.org/10.1016/j.neuroimage.2017.08.053 **Keywords**: fMRI; High-resolution; High-field; 7T; Multivariate pattern analysis; MVPA; Naturalistic stimuli; Movies; Eye tracking ********************************************************************** ### Data Files *NOTE: This dataset comprises 7 subjects, 4 with >16 movie stimulus repetitions. Of the original 10 subjects three were discarded without analysis due to subsequent changes in the experimental protocol (MRI sequences).* #### fMRI data ##### `sub-02_ses-05_task-Mx1_acq-Hr_run-2_bold.nii.gz` One run of BOLD fMRI data in [Nifti](https://nifti.nimh.nih.gov) format (.nii.gz). - `sub-##` : human subject number ## - `ses-##` : experimental session number ## (1-5 separate sessions per subject) - `task-*` : stimulus presented (5' movie clip) - `task-Mx1` : The Matrix I opening scene - `task-Mx2` : The Matrix II - `task-Gbu1` : The Good, the Bad, and the Ugly - `tast-ffMRI` : single-slice (fast) fMRI with high temporal resolution without stimulus e.g. for characterizing cardiac artifacts - `acq-Hr` / `acq-Lr` : Higher- / Lower-resolution fMRI at 1.2mm / 2mm isotropic - `run-#` : experimental run number within each fMRI session in temporal order #### MRI anatomy ##### `sub-02_ses-05_acq-AnaGE_T2w.nii.gz` : gradient-echo anatomy (magnitude) ##### `sub-02_ses-05_acq-AnaGEp_T2w.nii.gz` : gradient-echo anatomy (phase) #### Eye-tracking data ##### `sub-02_ses-05_task-Mx1_acq-Hr_run-2_vpdat.txt` - `*_vpset0.txt` : calibration before movie start - `*_vpset1.txt` : calibration at movie start - **`*_vpdat.txt`** : eye-tracking data - `*_vpset2.txt` : calibration at movie end - `*_vpset3.txt` : calibration after movie end
创建时间:
2025-09-11
5,000+
优质数据集
54 个
任务类型
进入经典数据集
二维码
社区交流群

面向社区/商业的数据集话题

二维码
科研交流群

面向高校/科研机构的开源数据集话题

数据驱动未来

携手共赢发展

商业合作