five

Full scale, microscopically resolved tomographies of sandstone and carbonate rocks augmented by experimental porosity and permeability values

收藏
Figshare2022-11-09 更新2026-04-28 收录
下载链接:
https://figshare.com/articles/dataset/Full_scale_microscopically_resolved_tomographies_of_sandstone_and_carbonate_rocks_augmented_by_experimental_porosity_and_permeability_values/21375565
下载链接
链接失效反馈
官方服务:
资源简介:
About the Data We report a dataset containing full-scale, three-dimensional images of rock plugs for application in digital rock and capillary network analysis. Specifically, we have acquired microscopically resolved tomography datasets of 18 cylindrical sandstone and carbonate rock samples having lengths of 25.4 mm and diameters of 9.5 mm, respectively. The rock plug samples measured in this work have porosity and permeability values ranging from 8% to 30% and 0.4 mD to above 5D, respectively. Dataset Structure Researchers interested in using this dataset will find five different volume types and formats for each sample. The suffix inside the parenthesis designates the naming scheme used for the dataset files: Full Frame (_grayscale_full): Data obtained from the reconstruction of the µCT projections. During reconstruction, the volume edges are removed but the largest inscribed parallelepiped within the plug is retained, thus leading to different sized parallelepipeds. Standard (_grayscale_standard): Volume cropped into a standard size of 2500x2500x7500 voxels. Cropped cubes (_grayscale_ROI-X) : 2500x2500x2500 voxel cubes extracted from the standard volume. The X designates the number of the cube, with values ranging from 1 to 3, cut top-down from the parallelepiped. Filtered cubes (_grayscale_filtered_ROI-X): Data obtained from the grayscale cubes through the application of contrast enhancement and noise reduction filters. The X designates the number of the cube, with values ranging from 1 to 3, cut top-down from the parallelepiped. Binarized cubes (_binary_ROI-X): Binary image data obtained from the filtered grayscale cubes. Each grayscale cube was segmented at threshold level calculated using the Multi-Otsu algorithm with a number of classes set to three. The X designates the number of the cube, with values ranging from 1 to 3, cut top-down from the parallelepiped. Alongside the volumes described above, the following supporting information is also provided: HDR file: File containing the cube size information for each sample. Dataset_Information.xlsx: File containing the naming convention used for all files as well as possible name changes that may happen during file decompression. This file also includes all acquisition and reconstruction parameters for each of the measurements encompassed in this work. qrm_10w__ir_rec_tra_(horizontal/vertical).raw: Data obtained from a standard microCT Bar pattern (NanoPhantom, QRM) on its horizontal/vertical silicon target (for more information, please see: https://www.qrm.de/en/products/micro-ct-bar-pattern-phantoms-airnano-customized?downloadfile=1701&type=3451&cHash=b0f142fb5d4e64ceeb84d57e6bafb08b). These files can be used for estimating the spatial resolution of the measurements. File Naming The Dataset_Information.xlsx file contains the file naming scheme for each file type of each sample. After extracting the compressed files from the original .tar.bz2 formats, the filename may change. Please refer to the table in case there is any problems identifying the files. Further Information For further information on the methods used in this work, please check our related research paper at: https://www.nature.com/articles/s41597-023-02259-z
创建时间:
2022-11-09
二维码
社区交流群
二维码
科研交流群
商业服务