five

Computed tomography fluoroscopy-guided percutaneous biopsy of pulmonary nodules ≤ 10 mm: retrospective analysis of procedures performed during the COVID-19 pandemic

收藏
DataCite Commons2023-03-14 更新2024-08-26 收录
下载链接:
https://scielo.figshare.com/articles/dataset/Computed_tomography_fluoroscopy-guided_percutaneous_biopsy_of_pulmonary_nodules_10_mm_retrospective_analysis_of_procedures_performed_during_the_COVID-19_pandemic/22268792
下载链接
链接失效反馈
官方服务:
资源简介:
Abstract Objective: To evaluate the diagnostic performance of computed tomography (CT) fluoroscopy-guided percutaneous transthoracic needle biopsy (PTNB) in pulmonary nodules ≤ 10 mm during the coronavirus disease 2019 pandemic. Materials and Methods: Between January 1, 2020 and April 30, 2022, a total of 359 CT fluoroscopy-guided PTNBs were performed at an interventional radiology center. Lung lesions measured between 2 mm and 108 mm. Of the 359 PTNBs, 27 (7.5%) were performed with an 18G core needle on nodules ≤ 10 mm in diameter. Results: Among the 27 biopsies performed on nodules ≤ 10 mm, the lesions measured < 5 mm in four and 5-10 mm in 23. The sensitivity and overall diagnostic accuracy of PTNB were 100% and 92.3%, respectively. The mean dose of ionizing radiation during PTNB was 581.33 mGy*cm (range, 303-1,129 mGy*cm), and the mean biopsy procedure time was 6.6 min (range, 2-12 min). There were no major postprocedural complications. Conclusion: CT fluoroscopy-guided PTNB appears to provide a high diagnostic yield with low complication rates.