five

Maximum forces in tendon connections for the Kessler suture in the single-side sample experiment

收藏
Most Wiedzy Open Research Data Catalog2026-04-17 收录
下载链接:
https://mostwiedzy.pl/en/open-research-data/maximum-forces-in-tendon-connections-for-the-kessler-suture-in-the-single-side-sample-experiment,525024758558150-0
下载链接
链接失效反馈
官方服务:
资源简介:
The main objective of the all study was to assess the load capacity of a new implant device for knotless tendon anastomosis. During this series of experiments the load capacity of the traditional two-strand Kessler sutures (3-0 sutures) was examined. Tendons from fresh swine legs (commercially available) served as the biological material. All samples were subjected to a load-to-failure test in the single-side sample experiment (see figure 1). They were axially stretched with a constant elongation increase of 0.5 mm/s. The tests were conducted on the custom-designed TissueTester 1.0 (see figure 2).
提供机构:
Grzegorz Rotta; Szymon Grymek
二维码
社区交流群
二维码
科研交流群
商业服务