Supermarket application. Effects of sub-cooling on real R744 based transcritical plants in warm and hot climate. Data analysis.
收藏DataCite Commons2020-09-18 更新2025-04-16 收录
下载链接:
http://www.iifiir.org/clientBookline/service/reference.asp?INSTANCE=EXPLOITATION&OUTPUT=PORTAL&DOCID=IFD_REFDOC_0019023&DOCBASE=IFD_REFDOC_EN&SETLANGUAGE=EN
下载链接
链接失效反馈官方服务:
资源简介:
Several techniques are under development worldwide to expand the convenient use of Carbon Dioxide (R744) in region with high external temperature. This paper analyses the effect of a sub-cooling device in real R744 trans-critical plants for supermarket application. A sub-cooling device is a system able to assist a gas cooler to cool a stream of trans-critical R744 before its expansion in the high pressure valve. The aim of the study is to understand how much the presence of a sub-cooler device helps the efficient use of R744 for refrigeration in commercial application in the hot and warm temperature region. The use of the sub-cooler reduces the discharging temperature and pressure peaks, as well as the power peaks and the overall energy consumption. This paper analyses a collection of data coming from different stores equipped with sub-cooling in order to compare them with stores without the sub-cooling device. Stores with different sub-cooling techniques have been analyzed such as mechanical, groundwater and integration with A/C.
提供机构:
International Institute of Refrigeration (IIR)
创建时间:
2016-12-21