five

Collected FBG and electrical data on large format prismatic cells during thermal abuse in climate chamber

收藏
NIAID Data Ecosystem2026-05-02 收录
下载链接:
https://zenodo.org/record/10262033
下载链接
链接失效反馈
官方服务:
资源简介:
Hello, you will find here the data used for analysis in the publication "Innovative Early Detection of High-Temperature Abuse of Prismatic Cells and Post-Abuse Degradation Analysis Using Pressure and External Fiber Bragg Grating Sensors" Attached is the complete electrical, thermal and pressure dataset measued by the Scienlab measurement and control module (Scienlab - SL60/200/12BT4C) as well as the parallel FBG measurement during operation (FiSens - X400) on the standard rupture disc of the tested large format prismatic cells. General hints: Sign convention for the current corresponds to positive values (I>0) equal to charging of the battery cell. Only raw data is provided without filtering or restriction of the data range. The mearsurement frequency for the optical data during the test B1 and O1 was set to 2 Hz. The exception to these rules are the reference ICA measurements which are resticted to the relevant cycle (2nd C/20 cycle) for comparison. Best regards André Hebenbrock
创建时间:
2024-12-10
二维码
社区交流群
二维码
科研交流群
商业服务