遇见数据集

fmb-2021-0288 supplementary data

收藏
DataCite Commons2022-07-26 更新2025-04-15 收录
官方服务:

资源简介:

Aim: To evaluate the accuracy of two PCR-based techniques for detecting SARS-CoV-2 variant Alpha (B.1.1.7). Materials & methods: A multicenter prospective cohort with 1137 positive specimens from Slovenia was studied. A mutation-based assay (rTEST-COVID-19 qPCR B.1.1.7 assay) and amplification curve pattern analysis of the Allplex SARS-CoV-2 assay were compared with whole-genome sequencing. Results: SARS-CoV-2 variant Alpha was detected in 155 samples (13.6%). Sensitivity and specificity were 98.1 and 98.0%, respectively, for the rTEST-COVID-19 qPCR B.1.1.7 assay and 97.4 and 97.5%, respectively, for amplification curve pattern analysis. Conclusion: The good analytical performance of both methods was confirmed for the preliminary identification of SARS-CoV-2 variant Alpha. This cost-effective principle for screening SARS-CoV-2 populations is also applicable to other emerging variants and may help to conserve some whole-genome sequencing resources.

提供机构:
Future Science Group
创建时间:
2022-07-26
二维码
社区交流群
二维码
科研交流群
商业服务