Parameter Estimation and Shading Pattern Identification for Photovoltaic Modules: Measured PV data
收藏资源简介:
Contact information: Jieming Ma Xi'an Jiaotong-Liverpool University Suzhou, China. jieming84@gmail.com Dates of data collection: 2021/03 Geographic location: Xi’an Jiaotong-Liverpool University’s south campus (east longitude 120o75’, north latitude 31o28’) ------------------------------------------------------------------------------------------------------------ This directory contains the following datasets: ------------------------------ PV data (poly-crystalline XHYG-10W PV modules) Poly_1_1.mat Poly_1_2.mat Poly_1_3.mat Poly_2_1.mat Poly_2_2.mat Poly_2_3.mat Poly_3_1.mat Poly_3_2.mat Poly_3_3.mat Poly_4_1.mat Poly_4_2.mat Poly_4_3.mat ------------------------------ PV data ( mono-crystalline XKD-50W PV modules) Mono_1_4.mat Mono_1_5.mat Mono_1_6.mat Mono_2_4.mat Mono_2_5.mat Mono_2_6.mat Mono_3_4.mat Mono_3_5.mat Mono_3_6.mat Mono_4_4.mat Mono_4_5.mat Mono_4_6.mat --------------------------------------------------------------------- DOCUMENTATION FOR PV data In the experiments, we applied poly-crystalline XHYG-10W and mono-crystalline XKD-50W PV modules, whose technical parameters are listed as follows. PV module XHYG-10W XKD-50W Cell Technology Poly-Crystalline Mono-Crystalline Maximum Power 10 W 50W Voltage at Maximum Power Point 9V 17.82V Current at Maximum Power Point 1.12A 2.8A Open-circuit voltage 10.71V 22.02V Short-circuit current 1.23A 3.18A The number of cells 20 36 The experiments used four-series connected PV modules operating under both UICs and PSCs. The PV cellswere shaded by light films to simulate different PSCs. AYHT309 thermometer with Type-K thermocouple probes was installed to measure the temperature of the PV panels. The solar irradiance was measured by a standard 2 cm2 cm mono-crystalline PV cell which has been calibrated by the National Institute of Metrology, China. A Fluke F289C multimeter measured the cell’s short circuit current. A PROVA-1011 PV system analyzer has the capability of generating the I-V data under a specific environmental condition. In the dataset, there are 24 testing cases by using multiple-level numbering. The first item indicates the number of irradiance levels receiving by the applied PV string, while the second item represents the case number. For example, “4-2" means the second test case with four different irradiance levels. All the data were collected at the Xi’an Jiaotong-Liverpool University’s south campus (east longitude 120o75’, north latitude 31o28’) in March 2021. The column headings for the tabular data are defined as follows: I terminal current (A) V terminal voltage (V) T temperature (oC)
联系方式:马杰明,西安交通利物浦大学,中国苏州,电子邮箱:jieming84@gmail.com 数据采集时间:2021年3月 地理位置:西安交通利物浦大学南校区(东经120°75′,北纬31°28′) ------------------------------------------------------------------------------------------------------------ 本目录包含如下数据集: ------------------------------ 光伏(Photovoltaic,PV)数据(多晶XHYG-10W型光伏组件) Poly_1_1.mat Poly_1_2.mat Poly_1_3.mat Poly_2_1.mat Poly_2_2.mat Poly_2_3.mat Poly_3_1.mat Poly_3_2.mat Poly_3_3.mat Poly_4_1.mat Poly_4_2.mat Poly_4_3.mat ------------------------------ 光伏(Photovoltaic,PV)数据(单晶XKD-50W型光伏组件) Mono_1_4.mat Mono_1_5.mat Mono_1_6.mat Mono_2_4.mat Mono_2_5.mat Mono_2_6.mat Mono_3_4.mat Mono_3_5.mat Mono_3_6.mat Mono_4_4.mat Mono_4_5.mat Mono_4_6.mat --------------------------------------------------------------------- 光伏数据文档说明 本实验采用多晶XHYG-10W与单晶XKD-50W型光伏组件,其技术参数如下: 光伏组件型号 XHYG-10W XKD-50W 电池技术 多晶 单晶 最大输出功率 10 W 50 W 最大功率点电压 9 V 17.82 V 最大功率点电流 1.12 A 2.8 A 开路电压 10.71 V 22.02 V 短路电流 1.23 A 3.18 A 电池片数量 20 36 本实验采用四路串联的光伏组件,在不均匀日照条件(UICs)与局部遮阴条件(PSCs)下开展测试。通过透光薄膜遮挡光伏电池片以模拟不同程度的局部遮阴条件。搭载K型热电偶探头的AYHT309温度计用于测量光伏面板温度。太阳辐照度由经中国计量科学研究院校准的标准2 cm×2 cm单晶光伏电池进行测量。福禄克(Fluke)F289C万用表用于测量电池短路电流。PROVA-1011光伏系统分析仪可在特定环境条件下生成I-V特性数据。 本数据集中共包含24组测试案例,采用两级编号规则:第一级代表被测光伏串所接收的辐照度等级数,第二级代表测试案例编号。例如,"4-2"表示包含4种不同辐照度等级的第2组测试案例。所有数据均于2021年3月在西安交通利物浦大学南校区(东经120°75′,北纬31°28′)采集完成。 表格数据的列标题定义如下: I:端电流(单位:安培,A) V:端电压(单位:伏特,V) T:光伏面板温度(单位:摄氏度,℃)



