The impact of pulsed Electromagnetic Fault Injection on true random number generators
收藏NIAID Data Ecosystem2026-03-11 收录
下载链接:
https://zenodo.org/record/1443173
下载链接
链接失效反馈官方服务:
资源简介:
Random number acquisition from HECTOR daughter board and the clock signals of both decimator and Priority Encoder. The acquisition where done with a shift register between the output of Priority Encoder’s output and the scope (the same applies for the decimator’s output).
Folder is class by type of faults:
tmp_00_wb means two of Priority Encoder’s bits are stuck at 00.
tmp_01_wb means two of Priority Encoder’s bits are stuck at 01.
tmp_10_wb means two of Priority Encoder’s bits are stuck at 10.
tmp_11_wb means two of Priority Encoder’s bits are stuck at 11.
tmp_0_wb means one of Priority Encoder’s bit is stuck at 0.
tmp_1_wb means one of Priority Encoder’s bit is stuck at 1.
Decim_0_wb means one bit of decimator’s output stuck at 0.
Decim_1_wb means one bit of decimator’s output stuck at 1.
Curves are class as follows:
(Index means the acquisition number)
CIdecimIndex_0.trc files are the clock signal before decimation, i.e. the clock used to sample Priority encoder’s output.
COdecimIndex_0.trc files are the clock signal after decimation, i.e. the clock used to sample decimator’s output.
IrandDecim_Index_0.trc is the output of the Priority Encoder.
OrandDecim_Index_0.trc is the output of the Priority Encoder.
All trc files are binary files.
The file conditions_wb recap all the injection parameter used to obtain the different fault.
创建时间:
2020-01-24