five

Supplementary Material for: A case of a low Vault after posterior chamber acrylic phakic intraocular lens implantation

收藏
Figshare2023-04-11 更新2026-04-28 收录
下载链接:
https://figshare.com/articles/dataset/Supplementary_Material_for_A_case_of_a_low_Vault_after_posterior_chamber_acrylic_phakic_intraocular_lens_implantation/22502590
下载链接
链接失效反馈
官方服务:
资源简介:
When implanting a posterior chamber pIOL, it is crucial to maintain a safe distance. The patient was a 29-year-old man with high-degree bilateral myopia. In February 2021, posterior chamber acrylic pIOLs (Eyecryl Phakic TORIC; Biotech Vision Care, Gujarat, India) were implanted in both his eyes. After the surgery, the right eye vault was 6 μm, and the left eye vault was 350 μm. Moreover, the ACDendo values were 2270 and 2220 μm for the right and left eyes, respectively. In our case, we found a fairly high CLR in both eyes, but it was greater in the right eye. The CLR value was +455 in the right eye and +350 in the left eye. In our patient, anterior segment anatomical parameters were higher in the right eye than in the left eye, and a greater pIOL length was calculated for the right eye, but the vault was very low. In our opinion, this was associated with the high CLR in the right eye. If an even larger pIOL were implanted, there would have been a greater narrowing of the anterior chamber angle. Therefore, pIOL implantation in the right eye is contraindicated.