five

Nuclear heating on TF and neutronics and thermal hydraulics data

收藏
科学数据银行2024-04-19 更新2026-04-23 收录
下载链接:
https://www.scidb.cn/detail?dataSetId=694ac5d71e5e4716b567983649aa61c2
下载链接
链接失效反馈
官方服务:
资源简介:
The overall TF-coil deposition amounts to 17.86 kW, with the case contributing 51.7% and WP providing 48.3% of this total. the total nuclear heat of TF coils obtained through the homogenized model reached 17.46 kW, exhibiting a relative error of 2.2% compared with the detailed heterogeneous model. The average nuclear-heating densities of the cables, jackets, and insulators at HF conductor layer 1 were 3.35 × 10−4 W/cm3 , 4.34 × 10−4 W/cm3 , and 1.63 × 10−4 W/cm3 , respectively. The nuclear heat density of WP decreases exponentially along the radial direction. As for the nuclear-heating toroidal profile in the HF, the central turn exhibited a higher nuclear deposition than the corner turn. The temperature margin of steady-state mode and transient mode are 1.25K and 2.17K, respectively.