Investigation of magnetocaloric effect by the fast response infrared optical temperature probe.
收藏DataCite Commons2020-09-18 更新2025-04-16 收录
下载链接:
http://www.iifiir.org/clientBookline/service/reference.asp?INSTANCE=EXPLOITATION&OUTPUT=PORTAL&DOCID=IFD_REFDOC_0019333&DOCBASE=IFD_REFDOC_EN&SETLANGUAGE=EN
下载链接
链接失效反馈官方服务:
资源简介:
We present a new technique for experimental study of kinetics of phase transitions (PTs) and direct measurement of the magnetocaloric effect (MCE) in pulsed magnetic fields by using the fast response temperature probe with infrared fiber optical (IRFO) sensor. As a preliminary demonstration of the new technique, the results are presented of MCE measurements for Gd near Curie point: ΔTad = 21.3 K under pulsed magnetic field μ0H = 12.7 T, with 12.5 ms pulse duration and 1 MHz frequency response of the electronic measurement system.
提供机构:
International Institute of Refrigeration (IIR)
创建时间:
2016-12-28