Included are data from triaxial, single-inclined-fracture friction experiments. The experiments were performed with slide-hold-slide protocol on Utah FORGE gneiss at increased temperature. With a ~10 MPa normal stress, temperatures vary between experiments from room temperature up to 163 Celsius. Hold times vary during experiment from ~10^1 to ~10^5 seconds. Measured are the frictional response upon reactivation after a hold period, active acoustic data (P-wave velocity and amplitude) and passive acoustic data (acoustic emission occurrence and amplitude). There are two types of datafiles: (1) Datafiles containing the friction data, including the temperature and the active acoustic data measured during the experiment (AEXX_Gneiss_Vp_mixref4). The underscore _Vp means that it includes the Vp or P-wave velocity data, with _mixref meaning that we use a mixed reference point for calculating the P-wave velocity. And (2) the datafiles containing the passive acoustics data, a catalog of the acoustic emissions (AE's) measured during the experiment (AEcatalog_AEXX_runX), where AEXX matches the experiment number and runX denotes which part of the experiment the data was collected, matching the times where active acoustic data was collected. AE catalogs are split in two parts when the file size exceeds 1 GB to aid download/opening times.