Multicenter normative data for mesopic microperimetry
收藏资源简介:
This record contains the analysis and underyling data presented in the manuscript Pfau et al. 'Multicenter normative data for mesopic microperimetry'. Contents: 2024-08-30_Multicenter-Normal-Data.csv: Newly published normal data for mesopic microperimetry 2024-08-30_Analysis.R: Analysis script 2024-08-30_Vignette-to-create-normal-data.R: Software example to create normative maps The subfolders Figures and Tables show the analysis results. The folder Intermediary_Results contains the results of the cross-validation folds to assess model perfromance. To run the analysis code in 2024-08-30_Analysis.R, the following data is needed in addition: Astle et al. Data Brief. 2016 Aug 4;9:673-675. doi: 10.1016/j.dib.2016.07.061 The 2024-08-30_Multicenter-Normal-Data.csv file with the data contains the following columns: source: Describes the clinical site MachineID: ID of the MAIA device used for data collection ParticipantID: ID of the participant EID: ID of the eye eye: Laterality (either Right or Left) sex: Sex (f for female, m for male) age: Age in years ExamID: ID of the exam ExamBaselineID: ID of the corresponding baseline exam (-1 indicates that the exam itself is the baseline exam) GridUsed: Name of the grid falsepos: Rate of false positive responses to Heijl-Krakau stimulus presentations to the optic nerve head (blind spot) bcea63_area_deg2: Fixation stability in terms of the bivariate contour ellipse area covering 63% of the fixation points (in square degree) bcea95_area_deg2: Fixation stability in terms of the bivariate contour ellipse area covering 95% of the fixation points (in square degree) pointID: ID of the test point eccentricity: Eccentricity of the test point (in degree) x_coord: X-coordinate of the test point (in degree), negative values are temporal to the fovea and positive values are nasal to the fovea (in retinal space) y_coord: Y-coordinate of the test point (in degree), negative values are inferior to the fovea and positive values are superior to the fovea (in retinal space) sensitivity: Sensitivity at the test point (in dB)
本数据集涵盖Pfau等人发表于论文《"Multicenter normative data for mesopic microperimetry"》的分析内容与原始实验数据。 数据集具体内容如下: 1. 2024-08-30_Multicenter-Normal-Data.csv:最新发布的中间视觉微视野检查(mesopic microperimetry)正常数据集 2. 2024-08-30_Analysis.R:数据分析脚本 3. 2024-08-30_Vignette-to-create-normal-data.R:用于生成正常参考图的软件示例脚本 子文件夹说明: - 文件夹Figures与Tables存放本次分析的结果图表与表格 - 文件夹Intermediary_Results存放用于评估模型性能的交叉验证折次结果 运行2024-08-30_Analysis.R所需的额外补充数据来自:Astle et al. Data Brief. 2016 Aug 4;9:673-675. doi: 10.1016/j.dib.2016.07.061 以下为数据文件2024-08-30_Multicenter-Normal-Data.csv的各字段详细说明: - source:临床数据采集站点信息 - MachineID:数据采集所用MAIA设备的编号 - ParticipantID:受试者编号 - EID:眼部编号 - eye:眼别(取值为Right或Left,即右眼或左眼) - sex:受试者性别(f代表女性,m代表男性) - age:受试者年龄(单位:岁) - ExamID:本次检查编号 - ExamBaselineID:对应基线检查的编号(取值为-1时,表示本次检查即为基线检查) - GridUsed:本次检查所用的微视野检查网格名称 - falsepos:视乳头(盲点)区域Heijl-Krakau刺激测试的假阳性反应率 - bcea63_area_deg2:覆盖63%固视点的双变量轮廓椭圆面积(单位:平方度),用于量化评估固视稳定性 - bcea95_area_deg2:覆盖95%固视点的双变量轮廓椭圆面积(单位:平方度),用于量化评估固视稳定性 - pointID:测试点位编号 - eccentricity:测试点位的偏心度(单位:度) - x_coord:测试点位的X坐标(单位:度),负值代表视网膜黄斑中心凹颞侧,正值代表黄斑中心凹鼻侧 - y_coord:测试点位的Y坐标(单位:度),负值代表黄斑中心凹下方,正值代表黄斑中心凹上方 - sensitivity:测试点位的视网膜敏感度(单位:分贝dB)