资源简介:
Water quality samples are being collected using ISCO autosamplers at all wetland sites (that is, all sites except TS/Ph-9, 10, and 11). The autosamplers contain 24 1L bottles. Water is sampled by programming the autosamplers to take composite samples once every 3 days. These samples are a composite of four 250mL subsamples drawn every 18 hours (a sampling scheme that captures a dawn, noon, dusk, and midnight sample in every three day composite). The samples are collected every 3-4 weeks and analyzed for total phosphorus (TP), total nitrogen (TN), and salinity. When sites are visited to collect these samples, we also collect a grab sample that is immediately put on ice. A portion of these grab samples is filtered through a Whatman GF/F filter immediately upon return to the lab, and the filtered samples are analyzed for inorganic nutrients such as NO2-, NO3-, NH4+, SRP, and DOC. The unfiltered fraction of these grab samples is analyzed for TP, TN, and TOC. We use these montly grab samples to generate relationships between TP and SRP, and between TN and NO2- + NO3- + NH4+. Dissolved nutrients are measured using standard rapid flow analyzer (RFA) techniques. TP is analyzed with a modified Solorzano and Sharp (1980) technique. TN is measured with an Antec TN analyzer, TOC and DOC are quantified on a Shimadzu TOC Analyzer, and salinity is measured with a YSI conductivity meter. In addition to the regular water quality monitoring, we use the rain level actuators at all freshwater sites to trigger water sampling after rain events exceed a given threshold of duration and/or intensity. As currently programmed, when the threshold of = 2.5 cm of rain per hour is passed, the autosampler at that site collects a 500mL sample 30 minutes after the threshold has been reached. Rain event samples are collected, treated, and analyzed as all other water quality samples.

本研究在所有湿地样点(即除TS/Ph-9、10、11外的全部样点)中使用ISCO自动采样器采集水质样本。该类自动采样器搭载24个1升容量的采样瓶。通过编程设置自动采样器每3天采集一次混合水样,该混合水样由每18小时采集的4份250毫升子样混合而成——此采样方案可在每3天的混合样本中覆盖黎明、正午、黄昏与午夜四个时段的水样。样本每3至4周采集一次,检测指标包括总磷(total phosphorus, TP)、总氮(total nitrogen, TN)与盐度。在前往样点采集上述混合水样时,研究人员还会同步采集瞬时水样,并即刻将其置于冰上保存。返回实验室后,即刻对部分瞬时水样使用Whatman GF/F滤膜进行过滤,过滤后的水样用于检测亚硝酸盐(NO₂⁻)、硝酸盐(NO₃⁻)、铵根离子(NH₄⁺)、可溶性活性磷(soluble reactive phosphorus, SRP)与溶解性有机碳(dissolved organic carbon, DOC)等无机营养盐。未经过滤的瞬时水样分样则用于检测总磷、总氮与总有机碳(total organic carbon, TOC)。研究人员借助这些月度瞬时水样,构建总磷与可溶性活性磷、总氮与亚硝酸盐+硝酸盐+铵根离子之间的相关关系。溶解性营养盐采用标准快速流动分析仪(rapid flow analyzer, RFA)法进行检测。总磷的检测采用修正后的Solorzano与Sharp(1980)方法。总氮使用Antec TN分析仪进行检测,总有机碳与溶解性有机碳采用岛津(Shimadzu)TOC分析仪定量,盐度则通过YSI电导仪测定。除常规水质监测外,研究人员还在所有淡水样点安装雨量触发装置,当降雨事件的时长和/或强度达到设定阈值时,自动启动水样采集流程。按照当前的编程设置,当每小时降雨量达到2.5厘米及以上的阈值时,对应样点的自动采样器将在阈值触发后30分钟采集500毫升水样。降雨事件采集的水样,其处理与检测流程与其余常规水质样本完全一致。
创建时间:
2012-06-26
二维码
社区交流群
二维码
科研交流群
商业服务