Simultaneous EEG-fMRI - Confidence in perceptual decisions
收藏OpenNeuro2020-04-24 更新2026-03-14 收录
下载链接:
https://openneuro.org/datasets/ds002739
下载链接
链接失效反馈官方服务:
资源简介:
OpenNeuro curator note: This dataset was previously accessible at ds001512. The dataset was reuploaded due to privacy considerations.
EEG
EEG_data contains preprocessed EEG data (see below for preprocessing details). EEG_events contains event times and behavioural data. There is a file for each of the two experimental sessions of each subject.
EEG data
EEGdata: [number_of_valid_electrodes x data_samples] - EEG activity for all electrodes across time
fs: 1000 - sampling frequency (after preprocessing)
excludedchannels: [1 x number_of_electrodes] - indices of channels removed from analysis
EEG events
dotdirection: [1 x number_of_valid_trials] - direction of coherent motion in dot stimulus (1=left, 2=right)
choice: [1 x number_of_valid_trials] - subject's direction choice (1=left, 2=right)
accuracy: [1 x number_of_valid_trials] - accuracy of direction choice (1=correct, 0=incorrect)
RT: [1 x number_of_valid_trials] - response time on direction choice (milliseconds)
confidence: [1 x number_of_valid_trials] - confidence report
tstim: [1 x number_of_valid_trials] - onset of visual motion stimulus
tresp: [1 x number_of_valid_trials] - time of perceptual choice
tconf: [1 x number_of_valid_trials] - onset of confidence rating visual prompt
totaltrials: 160 - original number of trials in the experimental session
excludedtrials: [1 x number_of_trials] - indices of trials excluded from analysis
fMRI
"_bold" and "_events" files contain preprocessed fMRI data and relevant events, respectively, for each subject and experimental session.
fMRI events
dot_stim_validtrials - random dot motion stimulus, for valid trials only
dot_resp_validtrials - subjects' responses on the motion discrimination task, for valid trials only
rating_stim_validtrials - confidence rating visual prompt, for valid trials only
rating_firstresp_alltrials - first button press during confidence rating, for all trials where at least one button was pressed (valid + invalid trials); duration represents time difference between first and last button press
rating_allresp_alltrials - all motor activity during confidence rating, for all trials where at least one button was pressed (valid + invalid trials); each entry represents one button press; multiple consecutive entries can belong to the same trial)
rest_break - task-unrelated periods of time where subject received no visual stimulation
dot_stim_alltrials - random dot motion stimulus, for all trials in the session (valid + invalid trials)
rating_stim_alltrials - confidence rating visual prompt, for all trials where this was presented (valid + invalid trials)
motionparams_rotX - head motion parameters (rotation, x axis) in radians
motionparams_rotY - head motion parameters (rotation, y axis) in radians
motionparams_rotZ - head motion parameters (rotation, z axis) in radians
motionparams_translX - head motion parameters (translation, x axis) in mm
motionparams_translY- head motion parameters (translation, y axis) in mm
motionparams_translZ- head motion parameters (translation, z axis) in mm
***
METHODS OF EEG PREPROCESSING
Preprocessing of the EEG signals was performed using Matlab (Mathworks, Natick, MA). EEG signals recorded inside an MR scanner are contaminated with gradient artifacts and ballistocardiogram (BCG) artifacts due to magnetic induction on the EEG leads. To correct for gradient-related artifacts, we constructed average artifact templates from sets of 80 consecutive functional volumes centred on each volume of interest, and subtracted these from the EEG signal. This process was repeated for each functional volume in the dataset. Additionally, we applied a 12 ms median filter to remove any residual spike artifacts. We corrected for standard EEG artifacts and applied a 0.5-40 Hz band-pass filter to remove slow DC drifts and high frequency noise. All data were downsampled to 1000 Hz.
To remove eye movement artifacts, subjects performed an eye movement calibration task prior to the main experiment (with the MRI scanner turned off, to avoid gradient artifacts), where they were instructed to blink repeatedly several times while a central fixation cross was displayed in the centre of the computer screen, and to make lateral and vertical saccades according to the position of a fixation. We used principal component analysis to identify linear components associated with blinks and saccades, which were subsequently removed from the EEG data (Parra et al., 2005).
Next, we corrected for cardiac-related (i.e., ballistocardiogram, BCG) artifacts. To minimise loss of signal power in the underlying EEG signal, we adopted a conservative approach by only removing a small number of subject-specific BCG components, using principal component analysis. We relied on the single-trial classifiers to identify discriminating components that are likely to be orthogonal to the BCG. BCG principal components were extracted from the data after low-pass filtering (at 4 Hz), to extract the signal within the frequency range where BCG artifacts are observed. Subject-specific principal components were then determined (average number of components across subjects: 1.8). The sensor weightings corresponding to those components were projected onto the broadband data and subtracted out. Finally, data were baseline corrected by removing the average signal during the 100 ms prestimulus interval.
METHODS FOR FMRI PREPROCESSING
The first 10 volumes prior to task onset were discarded from each fMRI run to ensure a steady-state MR signal. Additionally, 13 volumes were discarded from the post-task period at the end of each block. The remaining 771 volumes were used for statistical analyses. Pre-processing of the MRI data was performed using the FEAT tool of the FSL software (http://www.fmrib.ox.ac.uk/fsl) and included slice-timing correction, high-pass filtering (>100 s), and spatial smoothing (with a Gaussian kernel of 8 mm full width at half maximum), and head motion correction (using the MCFLIRT tool). The motion correction preprocessing step generated motion parameters which were subsequently included as regressors of no interest in the general linear model (GLM) analysis (see fMRI analysis below). Brain extraction of the structural and functional images was performed using the Brain Extraction tool (BET). Registration of EPI images to standard space (Montreal Neurological Institute, MNI) was performed using the Non-linear Image Registration Tool with a 10-mm warp resolution. The registration procedure involved transforming the EPI images into an individual's high-resolution space (with a linear, boundary-based registration algorithm (Greve and Fischl, 2009) prior to transforming to standard space. Registration outcome was visually checked for each subject to ensure correct alignment.
创建时间:
2020-04-24