Cav3.2+/+ Mouse #410 CA1 EEG recording
收藏资源简介:
A Ca<sub>v</sub>3.2<sup>+/+</sup> mouse (internal #410) was implanted with an intrahippocampal electrode for electrohippocampal CA1 EEG recordings. The differential electrode of the TA10ETA-F20 transmitter (Data Science International, DSI, USA, technical specifications: weight 3.9 g, volume 1.9 cc, input voltage range ± 2.5 mV, channel bandwidth (B) 1–200 Hz, nominal sampling rate (f) 1000 Hz (f = 5 B), temperature operating range 34–41 °C) was positioned at the following stereotaxic coordinates: (+)-lead, caudal − 2 mm, lateral of bregma 1.5 mm (right hemisphere), and dorsoventral (depth) 1.5 mm. The epidural reference electrode was positioned on the surface of the cerebellar cortex at the following stereotaxic coordinates: (−)-lead, bregma − 6 mm and lateral of bregma 1 mm (right<br> hemisphere). The deep tungsten electrodes (FHC, USA) are encapsuled with epoxylite with an<br> impedance of 50–100 kΩ (measured at 1000 Hz) and a shank diameter of 250 μm. For further details on the Ca<sub>v</sub>3.2 mouse model, animal experimentation approval, anaesthesia, transmitter insertion, stereotaxic electrode implantation, postoperative pain management and recovery, please refer to Arshaad MI et al., 2021. EEG data were exported to NeuroScore 3.2.9306-1 (Data Sciences International, DSI, USA). As the NeuroScore file format does not allow free access to the data, we have exported the raw EEG data as asci.-files, so that they can easily be imported in secondary analysis software. Importantly, the exported EEG data represent raw EEG data. No filtering, no artefact detection and/or artefact removal have been carried out. Thus, it is the users responsibility to adequately pretreat the data before further processing and analysis. As described in Arshaad MI et al. (2021), filtering, artefact detection and removal was carried out using NeuroScore before further analysis. The EEG data are presented here as a zip-folder for size reasons. Four EEG recordings are exported: R1 (a first 24h long-term EEG recording 10 days post transmitter implantation), R2 (a second 24h long-term recording 17 days post transmitter implantation), U1 (a 6h EEG recording following the first urethane injection (800 mg/kg i.p.) at day 18 post transmitter implantation), U2 (a 6h EEG recording after a second urethane injection (800 mg/kg i.p.) at day 25 post transmitter implantation). In addition, relative activity values are exported for all four recordings. For details on the recording procedure, please refer to Arshaad MI et al. (2021).
本数据集涉及的Cav3.2<sup>+/+</sup>小鼠(内部编号#410)植入了海马内电极,用于海马CA1区脑电图(electroencephalogram, EEG)记录。所用TA10ETA-F20型发射器(数据科学国际公司,Data Science International, DSI,美国)的技术参数如下:重量3.9 g,体积1.9 cc,输入电压范围±2.5 mV,通道带宽(B)1~200 Hz,标称采样率(f)1000 Hz(f=5B),工作温度范围34~41 ℃。该发射器的差分电极定位立体坐标如下:(+)导联:相对于前囟(bregma)尾侧-2 mm、右侧半球旁开1.5 mm,背腹侧(深度)1.5 mm。硬膜外参考电极置于小脑皮质表面,定位立体坐标如下:(-)导联:相对于前囟-6 mm、右侧半球旁开1 mm。深部钨电极(FHC,美国)采用环氧基封装材料(epoxylite)封装,阻抗为50~100 kΩ(1000 Hz下测得),针杆直径250 μm。 关于Cav3.2<sup>+/+</sup>小鼠模型、动物实验伦理审批、麻醉、发射器植入、立体定向电极植入、术后镇痛与恢复的详细信息,请参阅Arshaad MI等(2021)的研究。 脑电图数据导出自NeuroScore 3.2.9306-1(数据科学国际公司,Data Sciences International, DSI,美国)。由于NeuroScore文件格式无法支持数据的自由访问,我们将原始脑电图数据导出为ASCII格式文件,以便于在二次分析软件中直接导入。需特别说明的是,本次导出的脑电图数据为原始未处理数据,未进行任何滤波、伪迹检测或伪迹剔除操作。因此,用户需在后续处理与分析前对数据进行恰当的预处理。如Arshaad MI等(2021)所述,既往研究中已通过NeuroScore完成滤波、伪迹检测与剔除后再开展后续分析。 考虑到文件大小,本次公开的脑电图数据以ZIP压缩包形式提供。本次共导出4组脑电图记录:R1(发射器植入后第10天采集的首次24小时长期脑电图记录)、R2(发射器植入后第17天采集的第二次24小时长期脑电图记录)、U1(发射器植入后第18天首次腹腔注射氨基甲酸乙酯(urethane,800 mg/kg)后采集的6小时脑电图记录)、U2(发射器植入后第25天第二次腹腔注射氨基甲酸乙酯(urethane,800 mg/kg)后采集的6小时脑电图记录)。此外,还导出了4组记录的相对活动度数值。关于记录流程的详细信息,请参阅Arshaad MI等(2021)的研究。