five

"Table 51" of "Polarization Measurements in pi+ p Elastic Scattering from 0.6-GeV/c to 2.65-GeV/c"

收藏
Mendeley Data2024-06-25 更新2024-06-28 收录
下载链接:
https://www.hepdata.net/record/6939
下载链接
链接失效反馈
官方服务:
资源简介:
THE FOLLOWING COMMENTS ARE TAKEN FROM THE PI N COMPILATION OF R.L. KELLY. THEY ARE THAT COMPILATION& apos;S COMPLETE SET OF COMMENTS FOR PAPERS RELATED TO THE SAME EXPERIMENT (DESIGNATED MARTIN74) AS THE CURRENT PAPER. (THE IDENTIFIER PRECEDING THE REFERENCE AND COMMENT FOR EACH PAPER IS FOR CROSS-REFERENCING WITHIN THESE COMMENTS ONLY AND DOES NOT NECESSARILY AGREE WITH THE SHORT CODE USED ELSEWHERE IN THE PRESENT COMPILATION.) /// MARTIN72 [J. F. MARTIN AND J. C. SLEEMAN,PRIV. COMM.,1972] -- PRELIMINARY VERSION OF SLEEMAN74 DATA. /// MARTIN72T [J. F. MARTIN,HEP/T/35(OXFORD THESIS),1972.] -- THESIS ON DATA ABOVE 1.4 GEV/C. /// SLEEMAN74 [J. C. SLEEMAN,PRIV. COMM.,1974.] -- DATA TAPE AND LISTING OF FINAL RESULTS OF THE EXPERIMENT. /// THRESHER74 [J. J. THRESHER,PRIV. COMM.,1974.] -- TWO ERRORS,STATISTICAL AND SYSTEMATIC,ARE RECORDED FOR EACH DATA POINT ON THE SLEEMAN74 DATA TAPE. DECIDING HOW TO USE THESE PROPERLY IN A FITTING PROGRAM IS NOT STRAIGHTFORWARD,PARTICULARLY SINCE (ACCORDING TO MARTIN72T AND THRESHER74) THE SYSTEMATIC ERRORS TEND TO BE SOMEWHAT CORRELATED BETWEEN DIFFERENT BINS. HOWEVER,THE CORRELATION BETWEEN THE STATISTICAL AND SYSTEMATIC ERROR IN A SINGLE BIN IS NOT LARGE,THE FIRST COMING MAINLY FROM EVENT COUNTING AND THE SECOND MAINLY FROM BACKGROUND ESTIMATION (SEE MARTIN72T). ON ADVICE OF THRESHER74 WE HAVE COMBINED THE STATISTICAL AND SYSTEMATIC ERRORS FOR EACH BIN IN QUADRATURE,AND HAVE NOT ATTEMPTED TO TAKE CORRELATIONS BETWEEN DIFFERENT BINS INTO ACCOUNT. /// MARTIN74 [J. F. MARTIN,RL-74-016,1974.] -- PREPRINT VERSION OF MARTIN75. NOT IDENTICAL TO MARTIN75. /// MARTIN75 [J. F. MARTIN,NP B89,253(1975)] -- PI+ P POL AT 68 MOMENTA BETWEEN 603 AND 2651 MEV/C. DONE AT NIMROD WITH LMN TARGET,SCINTILLATION COUNTER HODOSCOPES,AND CHERENKOV COUNTERS TO RESOLVE THE REGION OF KINEMATIC AMBIGUITY AND REDUCE BACKGROUND. THE NE IS RECORDED AS +/-6 PCT OVERALL AND +/-2 PCT RESIDUAL AT EACH MOMENTUM. THIS IS AN OVERSIMPLIFICATION AS DATA WERE TAKEN SIMULTANEOUSLY AT PAIRS OF MOMENTA SEPARATED BY ABOUT 1.9 PCT. THE RESIDUAL NE OF SUCH A PAIR IS 2 PCT,BUT THE NORMALIZATIONS FOR THE TWO MEMBERS OF THE PAIR ARE 100 PCT CORRELATED. THE MARTIN75 DATA ARE NOT THE SAME AS THE SLEEMAN74 DATA. /// COMMENTS ON MODIFICATIONS TO LOVELACE71 COMPILATION BY KELLY -- LOVELACE71 VERSION COMES FROM TWO PRELIMINARY VERSIONS OF THE DATA EARLIER THAN MARTIN72 (LOVELACE71IDS=BROWN70 AND SLEEMA71). MANY MAJOR DIFFERENCES. RUTHERFORD, POLARIZED TARGET.

以下注释均取自R.L.凯利的π-N(π介子-核子)相互作用汇编数据集。本注释集包含了汇编中针对与当前论文同属一项实验(编号为MARTIN74)的所有相关论文的完整注释。每篇论文的参考文献与注释前的标识符仅用于本注释集内部的交叉引用,未必与本汇编其他位置使用的短代码一致。 /// MARTIN72 [J. F. MARTIN与J. C. SLEEMAN,私人通信(Priv. Comm.),1972年] —— SLEEMAN74数据集的预发布版本。 /// MARTIN72T [J. F. MARTIN,HEP/T/35(牛津大学学位论文),1972年] —— 针对1.4吉电子伏特每光速(GeV/c)以上能区数据的学位论文。 /// SLEEMAN74 [J. C. SLEEMAN,私人通信(Priv. Comm.),1974年] —— 本实验最终结果的数据磁带与结果清单。 /// THRESHER74 [J. J. THRESHER,私人通信(Priv. Comm.),1974年] —— SLEEMAN74数据磁带的每个数据点均记录了统计误差与系统误差两类误差。在拟合程序中合理处理这类误差并非易事,尤其根据MARTIN72T与THRESHER74的描述,不同分箱的系统误差往往存在一定相关性。不过单个分箱内统计误差与系统误差的相关性并不显著:前者主要来自事例计数,后者则主要源于本底估计(详见MARTIN72T)。根据THRESHER74的建议,我们已对每个分箱的统计误差与系统误差以方和根法合并,且未考虑不同分箱间的相关性。 /// MARTIN74 [J. F. MARTIN,RL-74-016,1974年] —— MARTIN75的预印本版本,与MARTIN75并不完全一致。 /// MARTIN75 [J. F. MARTIN,《核物理B》(Nuclear Physics B)第89卷,第253页(1975年)] —— 68组π⁺p极化散射数据,动量范围覆盖603至2651兆电子伏特每光速(MeV/c)。实验在NIMROD加速器装置上开展,采用LMN靶、闪烁计数器描迹仪与切伦科夫计数器,用于解决运动学模糊区域并压低本底。归一化误差记录为整体±6%,各动量点的残余归一化误差为±2%。但该描述存在过度简化:实验数据是在间隔约1.9%的动量对组上同时采集的,此类动量对的残余归一化误差为2%,但该对组中两个数据点的归一化完全相关。MARTIN75数据集与SLEEMAN74数据集并不相同。 /// 关于凯利对LOVELACE71汇编集的修改注释 —— LOVELACE71版本的数据源自早于MARTIN72的两个预发布版本(LOVELACE71IDS=BROWN70与SLEEMA71),二者存在诸多显著差异。实验地点为卢瑟福实验室,采用极化靶。
创建时间:
2023-06-28
二维码
社区交流群
二维码
科研交流群
商业服务