Double skin facades (DSFs) are building envelope systems defined by complex phenomena and non-linear-processes that make characterizing their performance a non-trivial task. In an effort to enable the scientific community to access experimental data for further analysis or model validation purposes, we release together with the open-access paper entitled “<strong><em>Laboratory testbed and methods for flexible characterization of the thermal and fluid dynamic behavior of double skin facades” (</em></strong><strong><em>https://doi.org/10.1016/j.buildenv.2021.108700</em></strong><strong><em>)</em></strong>, a set of experimental data collected during tests carried out with the use of the newly developed testbed. The data contains the results of a series of tests where various configurations of a full-scale DSF mock-up that have been subjected to different boundary conditions replicated in a climate simulator. The database contains a guide in the form of the file ‘Guide.pdf’, which explains how to read data, presents a schematic drawing of sensor layout, and provides more information on sensors’ positions. Further information on the original aims of the experiments, methods, and other data can be found in the article mentioned above, which becomes an essential tool to understand how to read and interpret the experimental data fully. The following collection of experimental data are provided: 32 steady-state measurements where the following factors were changed: ventilation mode (indoor and outdoor air curtain), solar irradiance (0, 400, 600, and 800 Wm<sup>-2</sup>), outdoor chamber temperature (10, 20, 30, and 40 ℃), cavity depth (20, 30, 40 and 60 cm) and venetian blinds position (no blinds, closed blinds, θ=45 º, and open blinds) [file names: ‘Taguchi_4Lx4F_L16_I-I.csv’ and ‘Taguchi 4Lx4F_L16_O-O.csv’], Dynamic profile measurements corresponding to a typical hot summer day [Dynamic_profile_measurements.csv] and Calibration data [Callibration.csv]. Any inquires on the experimental data<em> can be sent </em>to: aleksandar.jankovic@ntnu.no

双层表皮幕墙(Double Skin Facades, DSFs)是一类建筑围护结构系统,其性能表征因涉及复杂现象与非线性过程而极具挑战性。为支持科学界获取实验数据以开展进一步分析或模型验证工作,我们随题为《双层表皮幕墙热工与流体动力学行为柔性表征的实验平台及方法》的开放获取论文(DOI: https://doi.org/10.1016/j.buildenv.2021.108700)一并发布了基于该全新研发的实验平台开展测试所采集的系列实验数据。 本数据集包含一系列测试的结果:测试对象为全尺寸双层表皮幕墙实体模型,在气候模拟器中复现了不同边界条件,并对模型的多种配置方案进行了测试。数据集附带名为"Guide.pdf"的使用指南文件,其中说明了数据读取方法、展示了传感器布置示意图,并补充了传感器位置的详细信息。 关于实验的原始目标、测试方法及其他数据的更多细节,可参阅上述开放获取论文,该论文是完整理解与解读本实验数据的核心参考资料。本次发布的实验数据集包含以下内容:32组稳态测量数据,测试中调整的参数包括:通风模式(室内空气幕、室外空气幕)、太阳辐照度(0、400、600、800 W/m²)、室外腔体温升(10、20、30、40 ℃)、空腔深度(20、30、40、60 cm)以及遮阳百叶位置(无百叶窗、闭合百叶窗、θ=45°、开启百叶窗),对应文件为"Taguchi_4Lx4F_L16_I-I.csv"与"Taguchi 4Lx4F_L16_O-O.csv";对应典型炎热夏日的动态剖面测量数据,文件名为"Dynamic_profile_measurements.csv";以及校准数据,文件名为"Callibration.csv"。 若对本实验数据集有任何疑问,请发送邮件至:aleksandar.jankovic@ntnu.no

提供机构:
Zenodo
创建时间:
2021-12-28
二维码
社区交流群
二维码
科研交流群
商业服务