five

Unbonded Post-Tensioned Cast-in-Place Concrete Walls For Seismic Resistance: Wall 1

收藏
DataCite Commons2020-08-19 更新2025-04-16 收录
下载链接:
https://www.designsafe-ci.org/data/browser/public/nees.public/NEES-2012-1132.groups/Experiment-1
下载链接
链接失效反馈
官方服务:
资源简介:
The objective of the test was to study the behavior and performance of unbonded post-tensioned cast-in-place wall with low ratio of post-tensioned steel to reinforcement steel. The wall was subjected to quasi-static cyclic loading. Load control as well as displacement control loading modes were applied to the specimen. The loading protocol was based on ACI ITG-5.1-07. There were three cycles for each given drift. Shear failure was the failure mode observed during the experiment.
提供机构:
Network for Earthquake Engineering Simulation (NEES)
创建时间:
2015-02-03
二维码
社区交流群
二维码
科研交流群
商业服务