遇见数据集

Permeability, not viscosity, controls water transport through oil-cloaking films

收藏
Zenodo2026-09-28 更新2026-10-01 收录
官方服务:

资源简介:

Data for: Permeability, not viscosity, controls water transport through oil-cloakingfilmsParth Patil1, Abhishek Aggarwal1,2,3, Subramanian K.R.S. Sankaranarayanan1,2, SushantAnand1,4*1 Department of Mechanical and Industrial Engineering, University of Illinois Chicago, USA2 Center for Nanoscale Materials, Argonne National Laboratory, Argonne IL 60439, USA3 Mehta Family School of Sustainability, Indian Institute of Technology Indore, Madhya Pradesh453232, India4 Department of Chemical Engineering, University of Illinois Chicago, USA *Sushant AnandEmail: sushant@uic.edu CONTENTS Fig 1,2,3 - Ambient conditions.xlsx Temperature and relative humidity during the runs shown in Figures 1 and 2. One sheet per case. Fig 1,2,3 - Mass traces of all cases.xlsx Droplet mass against time for the same runs. Fig 4 - Ambient conditions.xlsxFig 4 - Evaporation of volatile oils.xlsxFig 6 - Ambient conditions.xlsxFig 6 - Film thickness effect on evaporation.xlsx Same structure, for Figures 4 and 6. Fig 1,2,3,4,6 - Raw edf files - Experimental.zip The as-acquired Sensirion logs behind every ambient-conditions workbook above, unmodified. Fig 5 - MD Simulation_Data_files.zip LAMMPS data and parameter files, and the input script, for the simulations in Figure 5. Movie S1.mov Hygroscopic growth of a 4 μL droplet of ~41 wt% aqueous CaCl2 at~90% ambient relative humidity (RH) is shown in the top video (scale bar, 1 mm). Evaporation ofa 12.5 μL water droplet at ~10% RH is shown in the bottom video (scale bar, 1 mm). Figure 3 is calculated from the rate constants fitted to the mass traces inFigures 1 and 2 and has no data file of its own. AMBIENT MEASUREMENTS Sensirion SHT4xA, serial 4029183529, on a SensorBridge, logged at 2 Hz withControlCenter 1.38.0. The .edf files are the raw instrument output. They are tab-delimited UTF-8 textwith a header of '# key=value' lines, followed by the columns Epoch_UTC,Local_Date_Time, temperature and relative humidity. No Sensirion software isneeded to read them. TRIMMING Logging was started before each experiment and stopped at or near its end, soevery log is longer than the run it contains. The ambient-conditions workbookshold only the window used in the analysis: a span equal to the experimentduration, ending either at the end of the log or, where the enclosure was openedbefore logging stopped, immediately before the step change in relative humiditythat marks it. Those step changes are accompanied by a simultaneous drop intemperature and are resolved to within one 0.5 s sample. Workbook columns are time_s, elapsed seconds from the start of the window;T_degC; and RH_percent. Time steps are the sensor's own and are close to but notexactly 0.5 s. No smoothing, filtering, interpolation or gap-filling was applied;values are as reported by the sensor. The raw logs are included so the discarded portion of each file can be recovered. MD SIMULATIONS LAMMPS version. Force field and its source. Which data/parameter paircorresponds to which system and run. What quantity was computed from each. LICENSE CC BY 4.0.

提供机构:
Zenodo
创建时间:
2026-09-28
二维码
社区交流群
二维码
科研交流群
商业服务