five

SMART Infrastructure Facility Building Data

收藏
Zenodo2020-07-08 更新2026-05-25 收录
下载链接:
https://zenodo.org/record/3935060
下载链接
链接失效反馈
官方服务:
资源简介:
<strong>SMART Building Data</strong> Authors: J. Barthelemy, B. Arshard, N. Verstaevel, P. Perez<br> Contact: SMART Infrastructure Facility - smart-iot@uow.edu.au<br> Version: 08 July 2020 <strong>Description</strong> The time series data has been generated by Droplet sensors installed in every room of the SMART Infrastructure Facility of the University of Wollongong. The sampling rate is set to one minute and the data is transmitted via a LoRaWAN network. Each device sense temperature, humidity, luminosity, pressure, movement and CO2 (*). In addition, they transmit their orientation (*), node id, room id and battery voltage. Each packet received by the LoRaWAN network is also characterized by a RSSI, an SNR and a checksum. The (*) CO2 and orientation data are not accurate. <strong>Data dictionary</strong> The dataset contains the following features: * info : the type of information for the current row. It can be: <br> - temp -&gt; temperature (Celcius)<br> - humidity -&gt; humidity (%)<br> - light -&gt; luminosity (1024 levels, 0 being the darkest and 1024 the brightest)<br> - co2 -&gt; CO2 (1024 levels, 0 being the lowest, 1024 the highest)<br> - pressure -&gt; pressure (hPa)<br> - orient -&gt; orientation of the sensor<br> - nodeId -&gt; internal id of the sensor<br> - roomNum -&gt; room id of the sensor<br> - voltage -&gt; battery voltage of the sensor (V)<br> - movement -&gt; motion detection (True/False)<br> - checksum -&gt; checksum of the packet transmitted via LoRaWAN<br> * room_id : the room id in which the sensor is installed (see map of the building)<br> * date_time : the timestamp of the data<br> * bool_v : boolean value (true/false) for movement<br> * str_v : string value for nodeId, checksum, roomNum<br> * long_v : integer (long) value for light, orient, rssi, co2, humidity<br> * dbl_v : real (double) value for voltage, pressure, temp, snr <strong>Notes</strong> - The uncompressed dataset is a 40Gb CSV file.<br> - Droplet sensors specifications: https://nube-io.com/wp-content/uploads/Droplet-Specifications-V5.0-1.pdf.<br> - More information about the SMART Infrastructure Facility is available here: https://www.uow.edu.au/smart/.

<strong>智能建筑数据集(SMART Building Data)</strong> 作者:J. Barthelemy、B. Arshard、N. Verstaevel、P. Perez<br> 联系方式:伍伦贡大学智能基础设施研究院(SMART Infrastructure Facility),邮箱:smart-iot@uow.edu.au<br> 版本:2020年7月8日 <strong>数据集说明</strong> 本数据集由伍伦贡大学智能基础设施研究院各房间内部署的Droplet传感器(Droplet sensor)生成,为时序传感数据。采样频率设置为每分钟1次,数据通过LoRaWAN网络(Long Range Wide Area Network)进行传输。每台传感器可采集温度、湿度、光照强度、气压、人体移动与二氧化碳(CO₂)数据(*),此外还会传输传感器朝向(*)、节点编号、房间编号与电池电压。LoRaWAN网络接收的每个数据包还会附带接收信号强度指示(Received Signal Strength Indicator, RSSI)、信噪比(Signal-to-Noise Ratio, SNR)与校验和。注(*):二氧化碳与传感器朝向数据的精度存在偏差。 <strong>数据字典</strong> 本数据集包含以下特征:* info : 当前行的信息类型,可选值包括:<br> - temp -> 温度(单位:摄氏度,℃)<br> - humidity -> 相对湿度(单位:百分比,%)<br> - light -> 光照强度(共1024个等级,0代表最暗,1024代表最亮)<br> - co2 -> 二氧化碳浓度(共1024个等级,0代表最低浓度,1024代表最高浓度)<br> - pressure -> 气压(单位:百帕,hPa)<br> - orient -> 传感器朝向<br> - nodeId -> 传感器内部编号<br> - roomNum -> 传感器所在房间编号<br> - voltage -> 传感器电池电压(单位:伏特,V)<br> - movement -> 人体移动检测结果(True/False,即检测到/未检测到)<br> - checksum -> LoRaWAN传输数据包的校验和<br> * room_id : 传感器安装所在的房间编号(可参考建筑平面图)<br> * date_time : 数据采集时间戳<br> * bool_v : 移动检测的布尔值(true/false,即是/否)<br> * str_v : 节点编号、校验和、房间编号的字符串类型取值<br> * long_v : 光照强度、传感器朝向、RSSI、二氧化碳浓度、相对湿度的整型(长整型)取值<br> * dbl_v : 电池电压、气压、温度、SNR的浮点型(双精度型)取值 <strong>备注</strong> - 未压缩的数据集为大小40GB的CSV文件(Comma-Separated Values)<br> - Droplet传感器规格文档:https://nube-io.com/wp-content/uploads/Droplet-Specifications-V5.0-1.pdf<br> - 更多关于智能基础设施研究院的信息可访问:https://www.uow.edu.au/smart/
提供机构:
Zenodo
创建时间:
2020-07-08
二维码
社区交流群
二维码
科研交流群
商业服务