five

Using electrical profilings, soundings and resistivity tomography for groundwater reservoirs exploration in cristalline area of Man (West Côte d’Ivoire)

收藏
doi.org2025-01-15 收录
下载链接:
http://doi.org/10.17632/23yjn625pr.1
下载链接
链接失效反馈
官方服务:
资源简介:
In order to collect electrical resistivity tomography data, an IRIS Instrument Syscal R1 Plus resistivity-meter was used in conjunction with a multicore-based connection device capable of concurrently connecting up to 32 electrodes spaced 5 m apart. As a result, the overall length of each ERT profile was 155 m. Electrical Resistivity Tomography (ERT) survey used a Wenner alpha array configuration for electrical resistivity data acquisition. The application of the Electrical resistivity tomography (ERT) Method, in conjunction with the BERT python-based inversion approach, leads to the development of a dependable methodology for fault identification.and aquifer characterization in a cristalline rock area of Man (Côte d'Ivoire).

为收集电电阻率层析成像数据,本研究采用了 IRIS 仪器系统 SCAL R1 Plus 电阻率计,并配合一种基于多芯连接的设备,能够同时连接间距为 5 米的最多 32 个电极。因此,每个电电阻率层析成像剖面(ERT)的总长度达到了 155 米。在电电阻率层析成像(ERT)调查中,采用了 Wenner alpha 数组配置进行电电阻率数据的采集。将电电阻率层析成像(ERT)方法与基于 BERT Python 的反演方法相结合,在非洲科特迪瓦的曼地区(Man)的结晶岩石区域,开发出了一种可靠的故障识别和含水层特征描述的方法。
提供机构:
Mendeley Data
二维码
社区交流群
二维码
科研交流群
商业服务