Minor ion concentrations in OsmoSamplers that were recovered on R/V Atlantis Expedition AT39-01 with the ROV Jason-II (Depart October 2, 2018 and returned 11/2/2017).
收藏DataONE2025-03-09 更新2025-04-26 收录
下载链接:
https://search.dataone.org/view/sha256:4d215b5ba55656203c0998da16a75b9ed013c5202cfe4832b06b560a34145b1c
下载链接
链接失效反馈官方服务:
资源简介:
<p>These data will be submitted in Orcutt <em>et al.</em>: “Subsurface oceanic crust microbe-mineral biogeography from multi-year incubations at North Pond, Mid-Atlantic Ridge”</p>
<p>Similar, relevant data were published in Wheat et al., 2020.</p>
<p> </p>
<p>OsmoSampler descriptions:</p>
<ul>
<li>NP 2017 1383 B Acid-Addition OsmoSampler was deployed in IODP Hole 1383B on 4/22/12, removed from the borehole on 10/21/17 (J2-1032), and recovered on the ship on 10/22/17 (J2-1033). The pump worked as planned.</li>
<li>1383 C blue Acid-Addition OsmoSampler was deployed on the wellhead at IODP Hole 1383C on 4/08/14 (J2-771) and recovered on 10/21/17 (J2-1032). This sampler pumped more than expected, resulting in a salinity of 46 per mil in the fresh water reservoir. The timeline was adjusted for the excess pumping.</li>
<li>1383 C black Acid-Addition OsmoSampler was deployed on the wellhead of IODP Hole 1383C on 4/08/14 (J2-771) and recovered on 10/21/17 (J2-1032). This sampler pumped more than expected, resulting in a salinity of 24 per mil in the fresh water reservoir. The timeline was adjusted for excess pumping.</li>
<li>1383 C upper Acid-Addition osmoSampler was deployed in Hole U1383C on 11/6/11 and recovered on 10/16/17 (J2-1030). This sampler pumped more than expected, resulting in a salinity of 10 per mil in the fresh water reservoir. The timeline was adjusted for the excess pumping.</li>
<li>1382 A green Acid-Addition OsmoSampler was deployed on the wellhead of IODP Hole 1382A on 4/08/14 (J2-771) and recovered on 10/23/17 (J2-1028). This sampler pumped more than expected, resulting in a salinity of 71 per mil in the fresh water reservoir. The timeline was adjusted for the excess pumping.</li>
<li>Acid was added to four of the five sample streams. The exception was the 1382A Green Acid-Addition Osmosampler. Concentrations account for the addition of acid (HCl).</li>
<li>Hole U1383B downhole (DH) MBIO1 FLOCS OsmoSampler minor ion concentrations. The sampler was deployed on 4/22/12, removed from the borehole on 10/21/17, and recovered on 10/22/17. The pump worked as planned.</li>
<li>Hole U1383B downhole (DH) MBIO2 FLOCS OsmoSampler minor ion concentrations. The sampler was deployed on 4/22/12, removed from the borehole on 10/21/17, and recovered on 10/22/17. The pump worked as planned.</li>
<li>Hole U1383B downhole (DH) ENRICH FLOCS OsmoSampler minor ion concentrations. The ampler was deployed on 4/22/12, removed from the borehole on 10/21/17, and recovered on 10/22/17. The pump worked as planned.</li>
<li>Hole U1383C upper downhole (DH) MBIO FLOCS OsmoSampler minor ion concentrations. The sampler was deployed on 11/6/11. Samplers were recovered on 10/16/17. This sampler pumped more than expected, resulting in a salinity of 24 per mil in the fresh water reservoir. An additional 168 ml of borehole fluid was pulled into the pump. This additional fluid was not considered in the time estimate.</li>
<li>Hole U1383C lower downhole (DH) MBIO FLOCS OsmoSampler minor ion concentrations. The sampler was deployed on 11/6/11. Samplers were recovered on 10/16/17. This sampler pumped more than expected, resulting in a salinity of 40 per mil in the fresh water reservoir. An additional 279 ml of borehole fluid was pulled into the pump. This additional fluid was not considered in the time estimate.</li>
<li>Hole U1383C downhole (DH) upper enrichment OsmoSampler minor ion concentrations. The sampler was deployed on 11/6/11 and recovered on 10/16/17. This sampler pumped more than expected, resulting in a salinity of 27 per mil in the fresh water reservoir. An additional 188 ml of borehole fluid was pulled into the pump. This additional fluid was not considered in the time estimate.</li>
<li>Hole U1383C wellhead (WH) Blue JP FLOCS OsmoSampler minor ion concentrations. This Sampler was deployed on 4/08/14 (J2-771) and recovered on 10/20/17. This sampler pumped more than expected, resulting in a salinity o 33 per mil in the fresh water reservoir. An additional 255 ml of borehole fluid was pulled into the pump. This additional fluid was not considered in the time estimate.</li>
<li>Hole U1383C wellhead (WH) Blue Orcutt FLOCS OsmoSampler minor ion concentrations. This Sampler was deployed on 4/08/14 (J2-771) and recovered on 10/20/17. This sampler pumped more than expected, resulting in a salinity o 35 per mil in the fresh water reservoir. An additional 271 ml of borehole fluid was pulled into the pump. This additional fluid was not considered in the time estimate.</li>
<li>Hole U1383C wellhead (WH) JP middle horizon \"black\" FLOCS OsmoSampler minor ion concentrations. This sampler was deployed on 4/08/14 (J2-771) and recovered on 10/20/17. This sampler pumped more than expected, resulting in a salinity o 33 per mil in the fresh water reservoir. An additional 255 ml of borehole fluid was pulled into the pump. This additional fluid was not considered in the time estimate.</li>
<li>Hole U1383C wellhead (WH) Orcutt middle horizon \"black\" FLOCS OsmoSampler minor ion concentrations. This sampler was deployed on 4/08/14 (J2-771) and recovered on 10/20/17. This sampler pumped more than expected, resulting in a salinity o 28 per mil in the fresh water reservoir. An additional 217 ml of borehole fluid was pulled into the pump. This additional fluid was not considered in the time estimate.</li>
<li>Hole U1383C wellhead (WH) shallow horizon JP \"red\" FLOCS OsmoSampler minor ion concentrations. This sampler was deployed on 4/08/14 (J2-771) and recovered on 10/20/17. This sampler pumped more than expected, resulting in a salinity of more than 100 per mil in the fresh water reservoir. This additional fluid was not considered in the time estimate.</li>
<li>Hole U1383C wellhead (WH) shallow horizon Orcutt \"red\" FLOCS OsmoSampler minor ion concentrations. This sampler was deployed on 4/08/14 (J2-771) and recovered on 10/20/17. This sampler pumped more than expected, resulting in a salinity of more than 100 per mil in the fresh water reservoir. This additional fluid was not considered in the time estimate.</li>
<li>Hole U1382A downhole (DH) upper MBIO FLOCS OsmoSampler minor ion concentrations. This sampler was deployed on 10/11/11 and recovered on 10/20/17. The pump worked as planned.</li>
<li>Hole U1382A downhole (DH) lower MBIO FLOCS OsmoSampler minor ion concentrations. This sampler was deployed on 10/11/11 and recovered on 10/20/17. This pump worked as planned.</li>
<li>Hole U1382A wellhead (WH) green JP FLOCS OsmoSampler minor ion concentrations. Samplers deployed on 4/08/14 (J2-771) and recovered on 10/20/17. This sampler pumped more than expected, resulting in a salinity o 35 per mil in the fresh water reservoir. An additional 271 ml of borehole fluid was pulled into the pump. This additional fluid was not considered in the time estimate.</li>
<li>Hole U1382A wellhead (WH) green Orcutt FLOCS OsmoSampler minor ion concentrations. Samplers deployed on 4/08/14 (J2-771) and recovered on 10/20/17. This sampler pumped more than expected, resulting in a salinity fo 45 per mil in the fresh water reservoir. An additional 349 ml of borehole fluid was pulled into the pump. This additional fluid was not considered in the time estimate.</li>
</ul>
<p><br />
</p>
本数据集将提交至Orcutt等人的论文:《大西洋中脊北塘区多年培养实验获得的地下洋壳微生物-矿物生物地理学》
与之类似的相关数据集已发表于Wheat等人2020年的研究中。
OsmoSampler(渗透压采样器)说明:
- NP 2017 1383 B 酸化型OsmoSampler(渗透压采样器)于2012年4月22日部署于国际大洋发现计划(International Ocean Discovery Program,简称IODP)1383B钻孔,2017年10月21日从钻孔中取出(编号J2-1032),并于2017年10月22日在科考船上回收(编号J2-1033)。该采样器泵体运行正常。
- 1383 C 蓝色酸化型OsmoSampler(渗透压采样器)于2014年4月8日部署于IODP 1383C钻孔井口(WH,即Wellhead,编号J2-771),并于2017年10月21日回收(编号J2-1032)。该采样器泵抽量超出预期,导致淡水储层盐度达到46‰,因此针对过度泵抽调整了采样时序。
- 1383 C 黑色酸化型OsmoSampler(渗透压采样器)于2014年4月8日部署于IODP 1383C钻孔井口(WH,编号J2-771),并于2017年10月21日回收(编号J2-1032)。该采样器泵抽量超出预期,导致淡水储层盐度达到24‰,因此针对过度泵抽调整了采样时序。
- 1383 C 上段酸化型OsmoSampler(渗透压采样器)于2011年11月6日部署于U1383C钻孔,并于2017年10月16日回收(编号J2-1030)。该采样器泵抽量超出预期,导致淡水储层盐度达到10‰,因此针对过度泵抽调整了采样时序。
- 1382 A 绿色酸化型OsmoSampler(渗透压采样器)于2014年4月8日部署于IODP 1382A钻孔井口(WH,编号J2-771),并于2017年10月23日回收(编号J2-1028)。该采样器泵抽量超出预期,导致淡水储层盐度达到71‰,因此针对过度泵抽调整了采样时序。
- 五组采样流中有四组添加了酸化处理,仅1382A绿色酸化型OsmoSampler(渗透压采样器)未进行酸化。所有浓度数据均已扣除盐酸(HCl)酸化引入的试剂影响。
- U1383B钻孔井下(DH,即Downhole)MBIO1 FLOCS型OsmoSampler(渗透压采样器)微量离子浓度数据集。该采样器于2012年4月22日部署,2017年10月21日从钻孔中取出,2017年10月22日回收,泵体运行正常。
- U1383B钻孔井下(DH)MBIO2 FLOCS型OsmoSampler(渗透压采样器)微量离子浓度数据集。该采样器于2012年4月22日部署,2017年10月21日从钻孔中取出,2017年10月22日回收,泵体运行正常。
- U1383B钻孔井下(DH)ENRICH FLOCS型OsmoSampler(渗透压采样器)微量离子浓度数据集。该采样器于2012年4月22日部署,2017年10月21日从钻孔中取出,2017年10月22日回收,泵体运行正常。
- U1383C钻孔上段井下(DH)MBIO FLOCS型OsmoSampler(渗透压采样器)微量离子浓度数据集。该采样器于2011年11月6日部署,2017年10月16日回收。其泵抽量超出预期,导致淡水储层盐度达到24‰,且额外抽吸了168 mL钻孔流体,该额外抽吸的流体未纳入时序估算范围。
- U1383C钻孔下段井下(DH)MBIO FLOCS型OsmoSampler(渗透压采样器)微量离子浓度数据集。该采样器于2011年11月6日部署,2017年10月16日回收。其泵抽量超出预期,导致淡水储层盐度达到40‰,且额外抽吸了279 mL钻孔流体,该额外抽吸的流体未纳入时序估算范围。
- U1383C钻孔井下(DH)上段富集型OsmoSampler(渗透压采样器)微量离子浓度数据集。该采样器于2011年11月6日部署,2017年10月16日回收。其泵抽量超出预期,导致淡水储层盐度达到27‰,且额外抽吸了188 mL钻孔流体,该额外抽吸的流体未纳入时序估算范围。
- U1383C钻孔井口(WH)蓝色JP FLOCS型OsmoSampler(渗透压采样器)微量离子浓度数据集。该采样器于2014年4月8日部署(编号J2-771),2017年10月20日回收。其泵抽量超出预期,导致淡水储层盐度达到33‰,且额外抽吸了255 mL钻孔流体,该额外抽吸的流体未纳入时序估算范围。
- U1383C钻孔井口(WH)蓝色Orcutt FLOCS型OsmoSampler(渗透压采样器)微量离子浓度数据集。该采样器于2014年4月8日部署(编号J2-771),2017年10月20日回收。其泵抽量超出预期,导致淡水储层盐度达到35‰,且额外抽吸了271 mL钻孔流体,该额外抽吸的流体未纳入时序估算范围。
- U1383C钻孔井口(WH)JP中层“黑色”FLOCS型OsmoSampler(渗透压采样器)微量离子浓度数据集。该采样器于2014年4月8日部署(编号J2-771),2017年10月20日回收。其泵抽量超出预期,导致淡水储层盐度达到33‰,且额外抽吸了255 mL钻孔流体,该额外抽吸的流体未纳入时序估算范围。
- U1383C钻孔井口(WH)Orcutt中层“黑色”FLOCS型OsmoSampler(渗透压采样器)微量离子浓度数据集。该采样器于2014年4月8日部署(编号J2-771),2017年10月20日回收。其泵抽量超出预期,导致淡水储层盐度达到28‰,且额外抽吸了217 mL钻孔流体,该额外抽吸的流体未纳入时序估算范围。
- U1383C钻孔井口(WH)JP浅层“红色”FLOCS型OsmoSampler(渗透压采样器)微量离子浓度数据集。该采样器于2014年4月8日部署(编号J2-771),2017年10月20日回收。其泵抽量超出预期,导致淡水储层盐度超过100‰,该额外抽吸的流体未纳入时序估算范围。
- U1383C钻孔井口(WH)Orcutt浅层“红色”FLOCS型OsmoSampler(渗透压采样器)微量离子浓度数据集。该采样器于2014年4月8日部署(编号J2-771),2017年10月20日回收。其泵抽量超出预期,导致淡水储层盐度超过100‰,该额外抽吸的流体未纳入时序估算范围。
- U1382A钻孔井下(DH)上段MBIO FLOCS型OsmoSampler(渗透压采样器)微量离子浓度数据集。该采样器于2011年10月11日部署,2017年10月20日回收,泵体运行正常。
- U1382A钻孔井下(DH)下段MBIO FLOCS型OsmoSampler(渗透压采样器)微量离子浓度数据集。该采样器于2011年10月11日部署,2017年10月20日回收,泵体运行正常。
- U1382A钻孔井口(WH)绿色JP FLOCS型OsmoSampler(渗透压采样器)微量离子浓度数据集。该采样器于2014年4月8日部署(编号J2-771),2017年10月20日回收。其泵抽量超出预期,导致淡水储层盐度达到35‰,且额外抽吸了271 mL钻孔流体,该额外抽吸的流体未纳入时序估算范围。
- U1382A钻孔井口(WH)绿色Orcutt FLOCS型OsmoSampler(渗透压采样器)微量离子浓度数据集。该采样器于2014年4月8日部署(编号J2-771),2017年10月20日回收。其泵抽量超出预期,导致淡水储层盐度达到45‰,且额外抽吸了349 mL钻孔流体,该额外抽吸的流体未纳入时序估算范围。
创建时间:
2025-03-09



