Feature Discrimination
收藏OpenNeuro2018-11-08 更新2026-03-14 收录
下载链接:
https://openneuro.org/datasets/ds001590
下载链接
链接失效反馈官方服务:
资源简介:
Please cite the following references if you use these data:
Ballard, I.B, Wagner, S.M., McClure, S.M. Hippocampal Pattern Separation Supports Reinforcement Learning. Nature Communications. 2019.
https://rdcu.be/bpEQQ
Analysis code can be found at: https://github.com/iancballard/Hipp_Pattern_Separation_Code
This dataset is made available under the Public Domain Dedication and License
v1.0, whose full text can be found at
http://www.opendatacommons.org/licenses/pddl/1.0/.
We hope that all users will follow the ODC Attribution/Share-Alike
Community Norms (http://www.opendatacommons.org/norms/odc-by-sa/);
in particular, while not legally required, we hope that all users
of the data will acknowledge the OpenfMRI project and Ian Ballard in any publications.
Defacing
--------
Pydeface was used on all anatomical images to ensure deindentification of subjects. The code
can be found at https://github.com/poldracklab/pydeface
Known Issues
------------
- CRITICAL: We used a development multiband sequence that has three quirks relevant to data quality:
1) The uppermost slice is corrupted for most subjects, and should be discarded. Take care to do the same for the fieldmap opposite-phase images.
2) On most scans, the last 1-4 volumes are corrupted. It is important to crop these volumes because the high intensity of these images will interfere with preprocessing algorithms. As such, the automated QA reports generated by OpenNeuro will not be accurate.
3) The first 2 volumes of each scan are reconstruction related volumes that have been prepended. The experimental timing has been adjusted so that it lines up with the data (i.e., volume 1 corresponds to time 0 in the events file); however, it would be prudent to remove a larger number of volumes than normal. In the paper, I removed 8 volumes and subtracted 12 seconds from the events timing.
- 2 subjects have only 2 out of 3 runs of functional data due to data loss (18 and 23).
- A few subjects have 2 runs of DTI data, the majority do not.
- Sub 15 has faulty reaction time data
- Subject 4 has an anatomical image acquired in a different session with different parameters.