Dataset for Patrol Sequences of Out-of-Service Nodes in a Power Distribution Feeders
收藏资源简介:
This release comprises a fictional radial power distribution system located on a road-network from Piedmont, California, USA. The system nodes' coordinates rely on projection EPSG:4326 or WGS 84. The test case mainly comprises 46 switches and 68 buses, totalling two substations with two feeders each. The first substation, DS01, holds two connection points and 2041 customers distributed on 30 buses. The other substation, DS02, also with two connection points, contains 2656 customers distributed on 38 buses. Additionally, the nine interconnections switches provide diverse manoeuvre possibilities between the feeders, including internal manoeuvres, and support customers' relocation to other branches. Consequently, this scheme containing two critical infrastructures can be applied to fault simulations and in-field crews' operations, such as switch manoeuvring and routing. Following, a brief description of the nodes' fields: <strong>substation</strong>: it identifies the substation that the node is allocated <strong>feeder</strong>: it identifies the feeder that the node is allocated <strong>label</strong>: it is the ID for each node <strong>type</strong>: this field contains the type of each node; switch, bus, or root. This last one denotes that the node is a substation <strong>interconnection</strong>: it is flagged by "1" if the node is an interconnection switch, and "0" otherwise <strong>customers</strong>: it detains the number of customers for each bus <strong>x</strong>: latitude <strong>y</strong>: longitude geometry: this field contains the shapely's geometry object for each point Next, a brief description of the edges' fields: <strong>substation</strong>: it identifies the substation that the node is allocated <strong>feeder</strong>: it identifies the feeder that the node is allocated <strong>from</strong>: it is a node label as an endpoint of an edge in a graph representation <strong>to</strong>: it is a node label as an endpoint of an edge in a graph representation <strong>interconnection</strong>: it is flagged by "1" if the node is an interconnection switch, and "0" otherwise <strong>geometry</strong>: this field contains the shapely's geometry object for each point <br>
本数据集包含一套虚构的径向配电系统(radial power distribution system),其布设路径取自美国加利福尼亚州皮德蒙特(Piedmont)的道路路网。该系统节点的坐标采用EPSG:4326(即WGS 84)投影坐标系。 本测试用例主要包含46台配电开关(switch)与68段母线(bus),涵盖2座变电站(substation),每座变电站各配备2条馈线(feeder)。首座变电站DS01设有2个连接点,共承载2041名用户,分布于30段母线上;另一座变电站DS02同样设有2个连接点,承载2656名用户,分布于38段母线上。 此外,9台互联开关(interconnection switch)可实现馈线间多样化的调度操作,包括站内调度,并支持将用户负荷迁移至其他配电支路。因此,这套包含两类关键基础设施的系统可用于故障仿真以及现场运维作业,例如配电开关调度与路径规划。 以下为节点各字段的简要说明: <strong>变电站(substation)</strong>:用于标识节点所属的变电站 <strong>馈线(feeder)</strong>:用于标识节点所属的馈线 <strong>标签(label)</strong>:每个节点的唯一标识ID <strong>类型(type)</strong>:该字段用于标注节点类型,可选配电开关、母线或根节点(root),其中根节点代表变电站节点 <strong>互联标识(interconnection)</strong>:若节点为互联开关则取值为"1",否则为"0" <strong>用户数(customers)</strong>:表示该母线承载的用户数量 <strong>x</strong>:纬度(latitude) <strong>y</strong>:经度(longitude) <strong>几何信息(geometry)</strong>:该字段存储每个节点的Shapely几何对象(shapely's geometry object) 以下为边各字段的简要说明: <strong>变电站(substation)</strong>:用于标识该边所属的变电站 <strong>馈线(feeder)</strong>:用于标识该边所属的馈线 <strong>起点(from)</strong>:以节点标签表示的图结构中边的一个端点 <strong>终点(to)</strong>:以节点标签表示的图结构中边的另一个端点 <strong>互联标识(interconnection)</strong>:若该边关联的节点为互联开关则取值为"1",否则为"0" <strong>几何信息(geometry)</strong>:该字段存储每条边的Shapely几何对象(shapely's geometry object) <br>