Comparison of IsoCode STIX and FTA Gene Guard Collection Matrices as Whole-Blood Storage and Processing Devices for Diagnosis of Malaria by PCR

收藏
PubMed Central2026-05-16 收录
下载链接:
https://pmc.ncbi.nlm.nih.gov/articles/PMC87904/
下载链接
链接失效反馈
官方服务:
资源简介:
We compared two collection devices, IsoCode and FTA, with whole blood for the diagnosis of malaria by PCR (n = 100). Using whole blood as the reference standard, both devices were sensitive for the detection of single-species malaria infections by PCR (≥96%). However, the detection of mixed infections was suboptimal (IsoCode was 42% sensitive, and FTA was 63% sensitive).