Parameter Estimation and Shading Pattern Identification for Photovoltaic Modules: Measured PV data
收藏Mendeley Data2021-07-12 更新2026-04-09 收录
下载链接:
https://data.mendeley.com/datasets/pftv5xx26h
下载链接
链接失效反馈官方服务:
资源简介:
Contact information: Jieming Ma Xi'an Jiaotong-Liverpool University Suzhou, China. jieming84@gmail.com Dates of data collection: 2021/03 Geographic location: Xi’an Jiaotong-Liverpool University’s south campus (east longitude 120o75’, north latitude 31o28’) ------------------------------------------------------------------------------------------------------------ This directory contains the following datasets: ------------------------------ PV data (poly-crystalline XHYG-10W PV modules) Poly_1_1.mat Poly_1_2.mat Poly_1_3.mat Poly_2_1.mat Poly_2_2.mat Poly_2_3.mat Poly_3_1.mat Poly_3_2.mat Poly_3_3.mat Poly_4_1.mat Poly_4_2.mat Poly_4_3.mat ------------------------------ PV data ( mono-crystalline XKD-50W PV modules) Mono_1_4.mat Mono_1_5.mat Mono_1_6.mat Mono_2_4.mat Mono_2_5.mat Mono_2_6.mat Mono_3_4.mat Mono_3_5.mat Mono_3_6.mat Mono_4_4.mat Mono_4_5.mat Mono_4_6.mat --------------------------------------------------------------------- DOCUMENTATION FOR PV data In the experiments, we applied poly-crystalline XHYG-10W and mono-crystalline XKD-50W PV modules, whose technical parameters are listed as follows. PV module XHYG-10W XKD-50W Cell Technology Poly-Crystalline Mono-Crystalline Maximum Power 10 W 50W Voltage at Maximum Power Point 9V 17.82V Current at Maximum Power Point 1.12A 2.8A Open-circuit voltage 10.71V 22.02V Short-circuit current 1.23A 3.18A The number of cells 20 36 The experiments used four-series connected PV modules operating under both UICs and PSCs. The PV cellswere shaded by light films to simulate different PSCs. AYHT309 thermometer with Type-K thermocouple probes was installed to measure the temperature of the PV panels. The solar irradiance was measured by a standard 2 cm2 cm mono-crystalline PV cell which has been calibrated by the National Institute of Metrology, China. A Fluke F289C multimeter measured the cell’s short circuit current. A PROVA-1011 PV system analyzer has the capability of generating the I-V data under a specific environmental condition. In the dataset, there are 24 testing cases by using multiple-level numbering. The first item indicates the number of irradiance levels receiving by the applied PV string, while the second item represents the case number. For example, “4-2" means the second test case with four different irradiance levels. All the data were collected at the Xi’an Jiaotong-Liverpool University’s south campus (east longitude 120o75’, north latitude 31o28’) in March 2021. The column headings for the tabular data are defined as follows: I terminal current (A) V terminal voltage (V) T temperature (oC)
联系方式:马杰明,中国苏州西交利物浦大学,邮箱:jieming84@gmail.com
数据采集时间:2021年3月
数据采集地理位置:西交利物浦大学南校区(东经120°75′,北纬31°28′)
------------------------------------------------------------------------------------------------------------
本数据集文件夹包含以下两类光伏(Photovoltaic, PV)数据:
------------------------------
多晶硅XHYG-10W光伏组件数据集
Poly_1_1.mat、Poly_1_2.mat、Poly_1_3.mat、Poly_2_1.mat、Poly_2_2.mat、Poly_2_3.mat、Poly_3_1.mat、Poly_3_2.mat、Poly_3_3.mat、Poly_4_1.mat、Poly_4_2.mat、Poly_4_3.mat
------------------------------
单晶硅XKD-50W光伏组件数据集
Mono_1_4.mat、Mono_1_5.mat、Mono_1_6.mat、Mono_2_4.mat、Mono_2_5.mat、Mono_2_6.mat、Mono_3_4.mat、Mono_3_5.mat、Mono_3_6.mat、Mono_4_4.mat、Mono_4_5.mat、Mono_4_6.mat
---------------------------------------------------------------------
光伏数据说明文档
本实验采用多晶硅XHYG-10W与单晶硅XKD-50W两款光伏组件,其技术参数如下所示:
光伏组件型号 XHYG-10W XKD-50W
电池技术 多晶硅 单晶硅
最大功率 10 W 50 W
最大功率点电压 9 V 17.82 V
最大功率点电流 1.12 A 2.8 A
开路电压 10.71 V 22.02 V
短路电流 1.23 A 3.18 A
电池片数量 20 36
本实验采用四串连接的光伏组件,分别在不均匀光照条件(Uneven Irradiance Conditions, UICs)与部分遮阴条件(Partial Shading Conditions, PSCs)下开展测试。通过透光薄膜遮挡光伏电池片以模拟不同程度的部分遮阴效果。搭载K型热电偶探头的AYHT309温度计用于测量光伏面板的表面温度。太阳辐照度通过经中国计量科学研究院校准的标准2 cm × 2 cm单晶硅光伏电池进行采集。使用福禄克F289C万用表(Fluke F289C)测量该标准电池的短路电流。采用PROVA-1011光伏系统分析仪采集特定环境条件下的I-V特性数据。
本数据集共包含24组测试案例,采用多级编号规则进行标识:第一位数字代表待测光伏串所接收的辐照度等级总数,第二位数字代表该辐照度等级组合下的测试案例序号。例如,“4-2”代表包含4种辐照度等级的第2组测试案例。所有数据均于2021年3月,在西交利物浦大学南校区(东经120°75′,北纬31°28′)完成采集。
表格数据的列标题定义如下:
I:端子电流(单位:安培,A)
V:端子电压(单位:伏特,V)
T:组件温度(单位:摄氏度,℃)
创建时间:
2021-07-12