Test Sample Specifications Configuration: 3P9S (3 cells in parallel (bank), 9 banks in series) Module Nominal Capacity = 10.2 Ah Graphite / NCA Cells 18650 Cells Cycling Protocol - Normal Voltage Window Charge: CCCV at 1C up to 37.8 V and a C/20 cutoff current Discharge: CC at 1C down to 24.3 V Capacity Fade = 20 % Number of Cycles = 100 Cycling Protocol - Reduced Voltage Window Charge: CCCV at 1C up to 36.0 V and a C/20 cutoff current Discharge: CC at 1C down to 26.1 V Capacity Fade = 20 % Number of Cycles = 135
### 测试样品规格配置
采用3P9S构型(3颗电芯并联为一组,共9组串联),模组标称容量为10.2 Ah。测试电芯为石墨负极/镍钴铝(NCA)正极18650型电芯。
#### 循环测试规程——标准电压窗口
充电:以1C倍率采用恒流恒压(Constant Current Constant Voltage, CCCV)充电至37.8 V,截止电流为C/20;
放电:以1C倍率采用恒流(Constant Current, CC)放电至24.3 V;
该工况下容量衰减目标为20%,总循环次数为100次。
#### 循环测试规程——缩减电压窗口
充电:以1C倍率采用恒流恒压(Constant Current Constant Voltage, CCCV)充电至36.0 V,截止电流为C/20;
放电:以1C倍率采用恒流(Constant Current, CC)放电至26.1 V;
该工况下容量衰减目标为20%,总循环次数为135次。