five

Cyclic Tests of Cantilever CMU Wall Specimen C7 at WSU

收藏
DataCite Commons2020-08-02 更新2025-04-16 收录
下载链接:
https://www.designsafe-ci.org/data/browser/public/nees.public/NEES-2011-1045.groups/Experiment-38
下载链接
链接失效反馈
官方服务:
资源简介:
Wall Specimen C7 had a height-to-length aspect ratio of 2.0, four No. 6 vertical reinforcement bars located in the two outermost cells (jamb reinforcement) and one No. 4 vertical reinforcement bar located at mid-length, two No. 3 horizontal reinforcement bars spaced 8-in. on center, and zero axial load. The vertical reinforcement did not contain lap splices.

墙体试件C7的高长比为2.0,竖向配筋包含4根6号钢筋(布置于两个最外侧空腔内,作为边框配筋)与1根4号竖向钢筋,布置于跨中位置;横向配筋为2根3号钢筋,中心间距为8英寸;试验未施加轴向荷载。此外,竖向钢筋未设置搭接接头。
提供机构:
Network for Earthquake Engineering Simulation (NEES)
创建时间:
2013-06-13