Hippocampal stimulation during temporal lobe seizure
收藏DataCite Commons2024-07-01 更新2024-07-13 收录
下载链接:
https://dandiarchive.org/dandiset/001054/0.240701.1903
下载链接
链接失效反馈官方服务:
资源简介:
Four non-human primates were used for this study in two contemporaneous cohorts. One cohort (n=3 hemispheres) was implanted with the Medtronic RC+S stimulation (GIN cohort) and recording system connected to two 4-contact ring electrodes to evaluate three unilateral stimulation patterns: 7 Hz Ring ADMES, 20 Hz Dual Ring, and 125 Hz Dual Ring (analog of clinical stimulation). In an additional cohort (EPC cohort, n=2), two 12-contact segmented electrodes were implanted in the right hippocampus and connected to an externalized recording and stimulation system to allow more flexibility in the stimulation pattern. In this second cohort, 4 variations of stimulation were evaluated (7 Hz Full ADMES, 7 Hz Ring ADMES, 31 Hz Wide Ring, and 31 Hz Dual Ring).
本研究共纳入4只非人灵长类动物,分为两个同期队列。第一队列(GIN队列,n=3个大脑半球)植入美敦力(Medtronic)RC+S刺激记录系统,该系统连接2个4触点环形电极,用于评估3种单侧刺激模式:7Hz环形ADMES、20Hz双环形刺激、125Hz双环形刺激(临床刺激等效模式)。另一补充队列(EPC队列,n=2)中,2个12触点分段电极被植入右侧海马体,并连接至外置式记录刺激系统,以实现刺激模式的更高灵活性。在该第二队列中,共评估了4种刺激变体:7Hz全段ADMES、7Hz环形ADMES、31Hz宽环形刺激以及31Hz双环形刺激。
提供机构:
DANDI Archive
创建时间:
2024-07-01